L_TW2P_scPar_WinderTensionCtrlState

L_TW2P_scPar_WinderTensionCtrlState basic functions

(missing or bad snippet)

L_TW2P_scPar_WinderTensionCtrlState technology functions

Identifier

Data type

Description

lrLineJerk

LREAL

Jerk for inching mode with the 1 / d evaluation and for the purpose of compensation with regard to the clutch function

  • Unit: rev / s3

  • Initial value: 100000

lrJogLineAcc

LREAL

Acceleration for the inching mode with the 1 / d evaluation.

Selection of the value for the maximum acceleration speed variation.

  • Unit: mm/s2

  • Initial value: 100

lrJogLineDec

LREAL

Deceleration for the inching mode with the 1 / d evaluation.

Selection of the value for the maximum deceleration speed variation.

  • Unit: mm/s2

  • Initial value: 10

lrJogLineVel

LREAL

Speed for the inching mode with the 1 / d evaluation.

Selection of the maximum speed used for traversing.

  • Unit: mm/s
  • Initial value: 10

lrSyncLineAcc

LREAL

Acceleration for synchronising to line velocity

  • Unit: mm/s2

  • Initial value: 100

lrSyncLineDec

LREAL

Deceleration for synchronising to line velocity

  • Unit: mm/s2

  • Initial value: 100

lrWebBreakWindow

LREAL

Web break window

The current diameter is compared to the previous diameter across the web break window from the last calculation cycle.

  • Unit: x 100 % (1.0 = 100 %)

  • Initial value: 0.1 (10 %)

lrMaxDiam

LREAL

Maximum diameter

  • Unit: mm
  • Initial value: 180

lrMinDiam

LREAL

Minimum diameter

  • Unit: mm

  • Initial value: 50

rFiltTimeDiam

REAL

PT1 filter time for the current diameter (lrSetDiamOut)

  • Unit: s

  • Initial value: 0.05

lrDiamCalcRegularDist

LREAL

Regular calculation distance for the diameter

  • Unit: rev

  • Initial value: 1

lrDiamCalcReducedDist

LREAL

Reduced calculation distance for the diameter

  • Unit: rev

  • Initial value: 0.1

alrAdaptDiamX

ARRAY [1...9] OF LREAL

Grid points of the curve function for diameter loading

  • Values that may be applied to the analog input lrSetDiam.

  • Unit: mm

  • Initial values: 0, 100, 200, 300, 400, 500, 600, 700, 800

alrAdaptDiamY

ARRAY [1...9] OF LREAL

Grid points of the curve function for diameter loading

  • Function values for the diameter

  • Unit: mm

  • Initial values: 0, 100, 200, 300, 400, 500, 600, 700, 800

lrTensCurveCtrlScaled

LREAL

Gradient of the characteristic for the tension control open loop

  • Unit: x 100 % (1 = 100 %)

  • Initial value: 0

The value '1' causes a constant tensile force profile and thus a proportionally increasing setpoint for the diameter.

lrTensCurveStartDiamScaled

LREAL

Initial point of the characteristic for the tension control open loop

  • Unit: x 100 %

  • 1 = 100 % = lrMaxDiam parameter

  • Initial value: 0 (0 %)

lrLineVelRef

LREAL

Maximum line velocity

  • Unit: mm/s

  • Initial value: 1000

lrMinLineVel

LREAL

Minimum line velocity

Up to this velocity, the diameter is held.

  • Unit: mm/s

  • Initial value: 1

rFiltTimeMaterialCounter

REAL

Filter time constant for the material length counter (lrMaterialCounter output)

  • Unit: s

  • Initial value: 0 (filter is deactivated.)

lrSetMaterialPos

LREAL

Position of the material length counter

With a FALSEäTRUE edge at the xSetMaterialCounter input, the material length counter (lrMaterialCounter output) is set to the value in lrSetMaterialPos.

  • Unit: mm

  • Initial value: 0

lrMaxWndSpd

LREAL

Definition of the maximum winder shaft speed (at the output end).

  • Unit: rev/s

  • Initial value: 100

lrLineVelOffsetScaled

LREAL

Line speed offset for speed limitation

  • Unit: x 100 % (1 = 100 % = lrLineVelRef parameter)

  • Initial value: 0.1

lrTensRef

LREAL

Maximum permissible tensile force

  • Unit: N

  • Initial value: 50

lrTensRamp

LREAL

Acceleration ramp for the tensile force setpoint

  • Unit: N/s

  • Initial value: 50

rFiltTimeWndSpd

REAL

PT1 filter time for the winder shaft speed

  • Unit: s

  • Initial value: 0.01

rFiltTimeAccSpd

REAL

PT1 filter time for the line speed which is calculated for the speed via the diameter, for acceleration compensation

  • Unit: s

  • Initial value: 0.005

lrAccCmpsDeadBandTrqScaled

LREAL

Lagging range (dead band) for the current acceleration torque

  • Unit: x 100 % (1.00 = 100 %);
    reference variable: rated motor torque [Nm]

  • Initial value: 0.1 (10 %)

lrAccCmpsGainAcc

LREAL

Gain factor for the acceleration torque in positive direction

  • Unit: x 100 % (1.00 = 100 %)

  • Initial value: 1.05 (105 %)

lrAccCmpsGainDec

LREAL

Gain factor for the acceleration torque in negative direction

  • Unit: x 100 % (1.00 = 100 %)

  • Initial value: 0.95 (95 %)

lrConstMInertia

LREAL

Constant moment of inertia at the winder shaft

  • Unit: kgcm2

  • Initial value: 1

lrMaxMInertia

LREAL

Maximally permissible moment of inertia at the winder shaft

  • Unit: kgcm2

  • Initial value: 10

lrFricCurveStartTrq

LREAL

Initial friction for the linear friction compensation if the winder shaft is at a standstill.

  • Unit: Nm

  • Initial value: 0

lrFricCurveEndTrq

LREAL

Final friction for the linear friction compensation if the winder shaft is at a standstill.

  • Unit: Nm

  • Initial value: 0

rFiltTimeFricSetSpd

REAL

PT1 filter time for the winder shaft speed for friction compensation

  • Unit: s

  • Initial value: 0.01

eTensCtrlMode

L_TW2P_WinderTensionControlMode

Selection of the axis control mode for the reel

The mode is effective in winding mode when the tension control/regulation is activated.

  • Initial value: 0

0

"TorqueBased"

The torque control is activated in the drive when the technology module changes to the "TENSIONCTRL" state.

1

"SpeedBased"

Speed control is activated in the drive when the technology module changes to the "TENSIONCTRL" state.

dwSelectTensCurve

DWORD

Selection of the characteristic for tension control

  • Initial value: 0

0

Linear tensile force profile

1

Linear torque profile

2

Tensile force profile on the basis of a specified characteristic

alrTensCurve

ARRAY[1..65] OF LREAL

Characteristic for tension control open loop consisting of 65 values.

lrTensCtrlGain

LREAL

Controller gain

  • Initial value: 0

lrTensCtrlResetTime

LREAL

Controller reset time

  • Unit: s

  • Initial value: 0 (reset time deactivated)

eResetICtrlMode

L_TW2P_ResetICtrlMode

Mode for setting the function for resetting the correcting variable from the I component via the xResetICtrl input = TRUE

  • Initial value: 1

0

Instant

With a rising edge xResetICtrl = TRUE, the correcting variable from the I component is set to 0 immediately (abruptly).

1

Ramp

With a rising edge xResetICtrl = TRUE, the correcting variable from the I component is ramped to zero via the scPar.IrDancerPosCtrlResetTime parameter.

lrTensCtrlLimitPos

LREAL

Limitation of the tensile force controller correcting variable (output of the controller) in positive direction

  • Unit: [N]

  • Initial value: 2147483648 (0.5 x 232)

lrTensCtrlLimitNeg

LREAL

Limitation of the tensile force controller correcting variable (output of the controller) in negative direction

  • Unit: [N]

  • Initial value: -2147483648 (-0.5 x 232)

lrIdentFricMaxSpdScaled

LREAL

Speed for friction identification

  • Unit: x 100 % (1 = 100 % = max. speed at the lrWndSpdRef output)

  • Initial value: 0.9

lrIdentFricAccDec

LREAL

Acceleration for friction identification

  • Unit: revs/s2

  • Initial value: 1

rFiltTimeIdentFricSpd

REAL

PT1 filter time for the winder shaft speed for friction identification

  • Unit: s

  • Initial value: 0.0

rFiltTimeIdentFricTrq

REAL

PT1 filter time for the winder shaft friction torque for friction identification

  • Unit: s

  • Initial value: 0.05

dwSelectFricCurve

DWORD

For friction identification (input xFricCmps = TRUE):

Selection of the memory area in which the friction values identified are stored.

A maximum of 4 characteristics can be stored.

  • Initial value: 1

  • 1 ... 4: memory area 1 ... 4

For friction compensation (input xExecuteIdentFric = FALSEäTRUE)

Selection of the characteristic for friction compensation

  • 0: Linear friction characteristic (adjustable via lrFricCurveStartTrq parameter)

  • 1 ... 4: identified friction characteristic (memory area 1 ... 4)

rFiltTimeActTensIn

REAL

PT1 filter time for the current tensile force (lrActTensIn input)

  • Unit: s

  • Initial value: 0.005

lrHystLineVelFricComp

LREAL

Hysteresis for detecting the direction of line speed. Only used with friction compensation xFricComp = TRUE and a noisy line signal.
Maximum amplitude for line speed noise.

  • Unit: mm/s

  • Initial value: 0

lrActTensInGain

LREAL

Gain factor for the current tensile force (lrActTensIn input)

  • Initial value: 1

lrActTensInOffset

LREAL

Offset for the current tensile force (lrActTensIn input)

  • Initial value: 0

IrHystlineStandStill

LREAL

Hysteresis width for the line speed

This stabilises the noisy line speed and the direction recognition. After detecting the maximum noise amplitude of the input signal, set this value.

  • Unit: mm/s

  • Initial value: 0

rFiltTimeIdentMInertiaSpd

REAL

PT1 filter time for the speed at the winder shaft during the identification of the moment of inertia

  • Unit: s

  • Initial value: 0.01

rFiltTimeIdentMInertiaTrq

REAL

PT1 filter time for the torque at the winder shaft during the identification of the moment of inertia

  • Unit: s

  • Initial value: 0.005

lrIdentMInertiaMaxSpd

Scaled

LREAL

Maximum speed of the winder shaft during the identification of the moment of inertia

  • Unit: x 100 % (1.0 = 100 % = lrWndSpdRef)

  • Initial value: 0.2 (20 %)

lrIdentMInertiaMaxTrq

Scaled

LREAL

Maximum torque of the winder shaft during the identification of the moment of inertia

  • Unit: x 100 % (1.0 = 100 %)
    reference variable: rated motor torque

  • Initial value: 0.2 (20 %)

eAdaptSpdCtrlGainMode

L_TW2P_AdaptSpdCtrlGainMode

Mode selection for adaptation of the speed controller gain.

  • Initial value: 2

0

DiamToSquare; VP = f(d2)

1

Diam; VP = f(d)

2

Inertia; VP = f(J)

lrAdaptSpdCtrlLowLimit

LREAL

Lower limit of speed controller gain in the drive. The lrSetSpdCtrlGainAdaptOut adaptation value must not be smaller than the scPar value. lrAdaptSpdCtrlLowLimit.

  • Value range: 0 to 1

  • Initial value: 1.0 (100 %)

alrSpdCtrlGainAdaptX

ARRAY[1..9] OF LREAL

 

Characteristic function for speed control gain. The X axis corresponds to the scaled moment of inertia.

  • Unit: x 100 % (1 = 100 % = parameter lrMaxMInertia)

  • Initial values: [0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6]

alrSpdCtrlGainAdaptY

ARRAY[1..9] OF LREAL

 

Characteristic function for speed control gain. The Y axis corresponds to the gain factor of the speed controller.

  • Unit: x 100 % (1 = 100 %)

  • Initial values: [0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6]

lrReducedGainWindow

LREAL

Area of the system deviation with a reduced gain / sensitivity.

The lrReducedGainWindow parameter is used to set a tolerance range in which the system deviation is transmitted to the controller with a lower gain. The tolerance range is set above and below the setpoint.

  • Initial value: 0.0

lrReducedGain

LREAL

Gain of system deviation within the reduced sensitivity

The lrReducedGain parameter serves to set the value to which the gain is to be reduced in the defined tolerance zone. This means, in the tolerance zone, the reduced gain is active (lrReducedGain).

  • Initial value: 0.0

eTensCtrlStopMode

L_TW2P_TensionCtrlStopMode

 

Mode in which the winding process ("TENSIONCTRL" state) is stopped.

  • Initial value: 0

0

Holding

The axis is stopped via the deceleration (lrHaltDec) and the jerk (lrJerk).

1

Move ABS

Absolute travel/position: The axis travels to the target position (lrPos_Dist) with the velocity (lrVel), acceleration (lrAcc), deceleration (lrDec) and jerk (lrJerk).

2

Move Rel

Relative travel position: the axis is brought to a standstill with the velocity (lrVel), acceleration (lrAcc), deceleration (lrDec) and jerk (lrJerk) after the distance (lrPos_Dist) has been travelled.