Outputs
Basic functions
(missing or bad snippet)Technology functions
Identifier Data type | Description | |
|---|---|---|
scSignalFlow | Structure of the signal flow | |
xHoldDiamActive BOOL | Signals whether the diameter is held. Note: When this output is toggled, we recommend that the hysteresis function is used (scPar.lrHystlineStandstill parameter).
| |
TRUE | Internal or conditional external holding is active. | |
FALSE | The diameter is updated again after the distance has passed. | |
xDiamMax BOOL | TRUE | The maximum diameter has been reached. |
xDiamMin BOOL | TRUE | The minimum diameter has been reached. |
lrSetDiamOut LREAL | Current diameter calculated
| |
xWebBreak BOOL | TRUE | A web break has been detected. |
xSynchronised BOOL | TRUE | The axis setpoint is synchronous with lrSetLineVel. This status is not active if xWindingBusy = TRUE. |
xAccDecSync BOOL | TRUE | The synchronisation function is active. Synchronisation of the winder is carried out or cancelled. |
xWindingBusy BOOL | TRUE | Winding operation has been activated. |
xUnwind BOOL | Status bit for unwinder and rewinder Note: When this output is toggled, we recommend that the hysteresis function is used (scPar.lrHystlineStandstill parameter).
| |
TRUE | Unwinding mode active | |
FALSE | Winding mode active | |
xConstantTension BOOL | TRUE | Constant tension has been set automatically. |
xWndSpdLimit BOOL | TRUE | The speed limit has been reached |
lrSetMInertiaOut LREAL | Current moment of inertia at the winder shaft
| |
xIdentBusy BOOL | TRUE | The identification of the moment of inertia or the friction is being determined. |
xIdentDone BOOL | TRUE | The identification of the mass inertia or the friction has been completed. |
lrIdentMInertia LREAL | Identified moment of inertia at the winder shaft
| |
lrSetSpdCtrlGainAdaptOut LREAL | Adaptation of the speed controller gain
| |
lrMaterialCounter LREAL | Display the material length counter status Depending on the definition of the winding direction, the material length counter is incremented or decremented
| |
lrLimitLineVel LREAL | The maximum permitted line speed is determined from the calculated diameter and the scPar.lrMaxWndSpd parameter.
| |