MC_AbortTrigger

This FB serves to cut short a touch probe detection started by means of MC_TouchProbe.

 

 

 

MC_AbortTrigger

 

 

 

AXIS_REF

-

Axis

-

AXIS_REF

MC_TRIGGER_REF

-

TriggerInput

TriggerInput

-

MC_TRIGGER_REF

BOOL

-

Execute

Done

-

BOOL

Busy

-

BOOL

Error

-

BOOL

ErrorID

-

L_IE1P_Error

 

 

 

 

 

 

 

 

Note!

The same MC_TRIGGER_REF structure has to be connected that has been used to instruct the FB MC_TouchProbe .

Inputs/outputs

Name

Data type

Information/possible settings

Axis

AXIS_REF

Transfer of the axis data structure

Motion axes (AXIS_REF)

TriggerInput

MC_TRIGGER_REF

Transfer of the touch probe configuration

Inputs

Name

Data type

Information/possible settings

Execute

BOOL

FALSE รค TRUE

Abort touch-probe detection.

Outputs

Name

Data type

Value/meaning

Done

BOOL

TRUE

Touch-probe detection has been aborted.

Busy

BOOL

TRUE

Processing is running.

Error

BOOL

TRUE

An error has occurred. For details see ErrorID .

ErrorID

L_IE1P_Error

If Error = TRUE: Error number for the error that has occurred.