Parameter change-over
For up to 32 freely selectable parameters, this function provides a change-over between
four sets with different parameter values.
DANGER!Unexpected response of the motor shaft while the inverter is enabled.
Changed parameter settings can become effective immediately depending on the activating method set in 0x4046 (P755.00).
Possible consequences: Death, severe injuries or damage to property
▶
If possible, only carry out parameter changes while the inverter is disabled.
▶
Certain device commands or settings which might cause a critical state of the drive behaviour
can generally only be carried out when the inverter is inhibited.
can generally only be carried out when the inverter is inhibited.
Details
The parameter list is compiled in the same way as that of the "Favorites" via configuration. »EASY Starter« provides a user-friendly parameterisation dialog for this purpose.
Change-over to another value set can optionally be effected via corresponding device commands and/or special functions/triggers:
Device commands for parameter change-over