Security mechanisms

Product Defense in Depth

The following image shows the Defense in Depth product concept. For the sake of clarity, some details have been deliberately omitted.

Product Defense in Depth

The core concept of the i9x0 servo inverter is that the fieldbus and Engineering Port interfaces are assigned to User Management via a firewall. The firewall minimizes the attack surface. Certificate handling takes over certificate management for the respective encrypted connections.

  • i9x0 User Management
    Connections to Lenze engineering tools, such as the PLC Designer and EASY Starter, are made through authorization in the context of user management on the i9x0. All access to the servo inverter is viewed through this User Management.

Special attention must be paid to fieldbuses. Protocols based on Ethernet are routed via the firewall, and access authorizations should be minimized as much as possible.Data via the fieldbuses themselves is not routed via the cybersecurity functions and runs directly into the application. Protection measures must be implemented in the component's environment.

The SD Card must be physically protected with an access control.

  • When accessing this component from the Tools menu, certificates are not checked within a Public Key Infrastructure (PKI) structure. Instead, the certificates are automatically trusted via an AutoTrust function. The application does not perform manual verification.
    * Without a PKI check or manual verification, attackers can use forged certificates to impersonate trusted entities and intercept sensitive data.
    * Attackers could create fake certificates to impersonate legitimate users or systems, which can lead to unauthorized access to confidential information.
    * Blind trust in certificates without verification can lead to malicious certificates being accepted, which jeopardizes the security of the entire system.

    Recommended measures:

    * Use additional security mechanisms such as intrusion detection systems (IDS) and perform regular security audits.

Expected Defense in Depth in the environment

The following image shows the Expected Defense in Depth in the environment of the i9x0 servo inverter.

Expected Defense in Depth in the environment

Conduit IT/OT gateway:

  • An IT security-protected network environment is mandatory for the operation of these components. Operation on the Internet is not permitted.

  • An IT/OT gateway is recommended to limit the attack surface so that only the absolutely necessary accesses and protocols are enabled.

  • As the components cannot have any DoS / DDoS protection mechanisms from an embedded device perspective, these must be connected externally upstream.

Conduit Tools:

  • Access from the engineering tools to the components must be limited in terms of organization and time.

  • The corresponding engineering tools must be operated on an up-to-date and IT-security-secured computer.

Conduit Fieldbus:

  • In most cases, the actual classic fieldbus protocol does not include any mechanisms to safeguard cyber security.

  • Measures to safeguard confidentiality, integrity and availability must be provided by the customer.

Conduit Field:

  • In most cases, the actual classic fieldbus protocol does not include any mechanisms to safeguard cyber security.

  • Measures to safeguard confidentiality, integrity and availability must be provided by the customer.

General Environment:

  • General physical access protection must be provided for the components. This applies in particular to the SD cards in the controllers.

  • Existing firmware updates for the i9x0 servo inverters as well as for all other components in the network should be installed immediately.

Security mechanisms:

The following security functions are included in the listed components.

  • Note:
    The functions mentioned are currently part of a prototypical firmware. If you are interested in this firmware, please contact your Lenze sales representative.

  • i9x0.SFTPServer

  • i9x0.SSHServer

  • i9x0.MinimumAndDefaultSecurity

  • i9x0.SecureFactoryReset

  • i9x0.Firewall

  • i9x0.UserManagement

  • i9x0.EncryptedCommunication.PLCDesigner

  • i9x0.CertificateStore.viaPLCDesigner

  • i9x0.OPCUAServer.Authentification

  • i9x0.OPCUAServer.Certificate

  • i9x0.Application.Encryption

  • i9x0.Application.Signature

  • i9x0.EncryptedApplicationData

  • i9x0.NTP

  • i9x0.SecureBoot

  • i9x0.FirmwareUpdate

  • i9x0.DeviceReplacement

  • i9x0.SysLog

  • i9x0.WebVisu.Activation

  • i9x0.WebVisu.Certificate

  • i9x0.WebVisu.UserManagement