Commissioning, Hardening and Decommissioning Notes and Organizational Measures
The following commissioning instructions must be followed.
General instructions
-
As far as possible, avoid connecting the i9x0 Servo Inverter to open networks or the internet. We recommend organizational and technical actions for the i9x0 Servo Inverter.
-
For protection, additionally use data link layers such as a VPN for remote access.
-
Install Firewall mechanisms, IPS (Intrusion Prevention Systems) and IDS (Intrustion Detection Systems).
-
Connecting external devices upstream to provide protection against DoS (Denial of Service) or DDos (Distributed Denial of Service).
-
Restrict access to authorized persons only. A particular focus here is on physical access to the SD card. This concerns access to the data on the SD card, but also the physical swapping of SD cards between servo inverters.
-
Change existing default passwords after the first start-up and also regularly afterwards. Please use only high-strength passwords.
-
As soon as the web visu functions of the i9x0 Servo Inverter (refer to chapter i9x0.WebVisu.Activation) are accessed with a browser, we recommend activating the logging functions of the browser and backing up the certificate store of the browser. In this way, communication to the i9x0 servo inverter can be traced.
Commissioning and hardening instructions
-
Change the Key for SFTP-Server-Communication (i9x0.SFTPServer).
-
Be sure, that there is no ‘.enable-ssh’ file on the SD card for SSH-Access (i9x0.SSHServer).
-
If you are using the i9x0-prog variant, please choose the security configuration (i9x0.MinimumAndDefaultSecurity).
-
In the event of accidental incorrect parameterization, the Secure Facory Reset can be used to return to the delivery status (refer to chapter i9x0.SecureFactoryReset).
-
Change the settings of the i9x0 Firewall for hardening the component (i9x0.Firewall).
-
Activate and use the User Management (i9x0.UserManagement).
-
Change the standard EngineeringItf-User-Password (i950.UserManagement: EngineeringItf) or delete this standard user.
-
Prevent the deletion of the User Management on the SD card via an organizational measure (i9x0.UserManagement).
-
Activate the function ‘Encrypted Communication’ (i9x0.EncryptedCommunication.PLCDesigner). If Encrypted Communication is not enabled, the communication is not protected against a man-in-the-middle attack.
-
Handle the certificates in the programming phase of the machine with the PLC Designer (i9x0.CertificateStore.viaPLCDesigner).
-
If you are using the OPC-UA Server, please use the Authentification
-
(i950.OPCUAServer.Authentificiation) and the Certificate handling
-
Activate encrypted application to secure the Application on the i9x0 (i9x0.Application.Encryption).
-
Activation and configuration of the NTP client (i9x0.NTP).
-
For users information, have a look at the secure boot (i9x0.SecureBoot).
-
If needed an firmware update, please use the EASY Firmware Loader (i9x0.FirmwareUpdate).
-
For easy device replacement the i9x0 has an specified replacement function (i9x0.DeviceReplacement).
-
Activate the SysLog functionality for logging security relevant events (i9x0.SysLog).
-
If using the WebVisu in the customer-specific variant, please hardening the communication and the web server (i9x0.WebVisu.Activation) (i9x0.WebVisu.Certificate) (i9x0.WebVisu.UserManagement)
When installed in a machine or customer environment, the security environment must ensure that the WebVisu browser (typically installed on a web panel) is located in the same security zone as the device, the i950 servo inverter.
Periodic security maintenance
-
It is recommended to check the password policy periodically for updates and to adjust the requirements if necessary.
-
It is recommended to change the passwords cyclically.
-
It is recommended to check the certificates used with regard to their key lengths for up-to-dateness and to generate new certificates with higher key lengths if necessary.
-
It is recommended to exchange the certificates regularly.
Decommissioning instructions
-
The device command 0x2022:001 "Device command: Load Lenze settings" must be executed. This resets all application settings.
-
It is recommended to update the firmware using the EASY Firmware Loader.
-
Remove the SD card and format it (in order to retain the Application Credits, the corresponding data must first be memorized and restored on the formatted SD card).
Removal of product from environment
-
It is recommended for all industrial communication partners of the i9x0 servo inverters to be removed, to change the trusted certificates of the i9x0 into untrusted certificates.
-
It is recommended to securely remove the login data for the controller to be removed, such as name and password for the necessary authentication, from all industrial communication partners.