i9x0.SecureFactoryReset

This function resets the i9x0 servo inverter and is available from firmware version V2.0.0.

i9x0 Secure Factory Reset

This functionality is executed in two stages:

  • In the first stage, a device command must be sent.

  • In the second stage, mains switching must be carried out within a specified time.

Necessary conditions:

  • The mains switching must take place physically on site, which means that the 24V must be switched on site. Executing a device command such as a reboot is not permitted. This also applies to the execution of the "set secure factory reset" command.

  • The timeout time is 60 seconds. The mains switching must take place within this time. If mains switching takes place after this time, no deletion routine is triggered.

  • Once the command has been executed correctly, the i9x0 Servo Inverter returns to its default state and the flashing pattern for Brand-New is visible again, however, is switched to "minimum security" as soon as it is switched on and is no longer visible(refer to chapter i9x0.MinimumAndDefaultSecurity).

Address

Name

Info

0x2022:052

set secure factory default

 

0

Deactivated

 

1

Activated