Service life diagnostics

Display of the current operating and switch-on time of the controller.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2D81:001
Life-diagnosis: Operating time
–
Read only: x s
 
Display of how long the device has been powered in total, regardless of the state of the soft PLC (RUN/STOP).
–
The counter cannot be reset.
 
–
The seconds are not updated.
 
–
Representation: d:h:m:00
 
0x2D81:002
Life-diagnosis: Power-on time
–
Read only: x s
 
Display of how long the device has been supplied with voltage since it was last switched on, regardless of the status of the soft PLC (RUN/STOP).
–
The counter starts again at 00:00:00:00 when the power is next switched on.
 
–
Representation: d:h:m:s
 
0x2D81:004
Life-diagnosis: Main switching cycles
–
Read only
 
Display of the number of switching cycles of the mains voltage.