EtherCAT slave
Chapter overview
EtherCAT® (Ethernet for Controller and Automation Technology) is an Ethernet-based fieldbus system which fulfils the application profile for industrial realtime systems.
–
EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
–
Detailed information on EtherCAT can be found on the web page of EtherCAT Technology Group (ETG): www.ethercat.org
EtherCAT device connection
–
The EtherCAT device connection is established using the RJ45 sockets X246 and X247.
–
A CAT 5/5e Ethernet cable can be used for the connection to the network, 2-pair with AWG22 or 4-pair with AWG22/24.
More information about connections can be found on the Internet:
www.ethercat.org
à
ETG.1600 EtherCAT Installation GuidelineTypical topology
|
Line
|
|
|
|
M
|
Master
|
|
|
|
SD
|
Slave device
|
|
|
|
Bus-related information
|
|||||
|
|
Name
|
|
EtherCAT
|
|
|
|
Communication medium
|
|
Ethernet 100 Mbps/s, full duplex
|
|
||
|
Application
|
|
Connection as EtherCAT slave
|
|
||
|
Status display
|
|
2 LEDs (BUS RUN, BUS ERR)
|
|
||
|
Connection designation
|
|
X246 (IN)
X247 (OUT)
|
|
||
|
Technical data
|
|||||
|
|
Communication profile
|
|
EtherCAT
|
|
|
|
|
CANopen over EtherCAT
|
|
|||
|
Safety over EtherCAT (FSoE)
|
|
No
|
|
||
|
Vendor ID [hex]
|
|
0x3B
|
|
||
|
Network topology
|
|
Line, tree, ring
|
|
||
|
Device
|
|
|
|
||
|
|
Type
|
|
EtherCAT slave
|
|
|
|
Max. number
|
|
65535
|
In the entire network
|
||
|
Address
|
|
Automatically assigned by the master
|
|
||
|
Max. cable length
|
m
|
Not limited
|
The decisive factor is the length between the devices.
|
||
|
Max. cable length between two devices
|
m
|
100
|
|
||
|
Process data
|
|
|
|
||
|
|
Transmit PDOs
|
|
0 ... 32
|
Max. 1024 bytes
2-, 4-, 8-, 16-, 32-, 64-, 96-word PDOs
|
|
|
Receive PDOs
|
|
0 ... 32
|
|||
|
Cycle time
|
ms
|
Integer multiple of 1 ms
|
|
||
|
Communication time
|
|||||
|
|
Communication time depending on
|
|
processing time in the controller
|
time between the start of a request and the arrival of the response
|
|
|
|
telegram runtime (transmission rate, telegram length)
|
||||
|
|
nesting depth of the network
|
||||
|
|
bus load
|
||||
|
Processing time of process data
|
|||||
|
|
Update cycle
|
ms
|
1
|
In the controller
|
|
|
Processing time
|
ms
|
0 ... 1
|
|||
|
Runtime of the application task of the technology application used (tolerance)
|
ms
|
1 ... x
|
|||
Commissioning