Current controller (field-oriented control)

For quick commissioning, the calculations and settings are made automatically during the motor calibration.
 
For typical applications, a manual adaptation of the parameters of the current controller is not recommended. An incorrect setting may have a negative effect on the control. For special applications, contact the manufacturer before adapting the parameters.
 
 
Preconditions
The current controller described here is only effective in the following motor control mode:
–
Sensorless control for synchronous motors (SLSM-PSM)
 
The current controller parameters are calculated based on the stator resistance and leakage inductance. Thus, the following parameters must be set correctly, either via optimization or manually (according to manufacturer-data/motor data sheet):
–
0x2C01:002: Stator resistance
 
–
0x2C03:005 (P352.05): D-axis inductance Ld
 
–
0x2C03:006 (P352.06): Q-axis inductance Lq
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2942:004
Current controller parameters: d-axis gain
0.00 ... [26.00]* ... 750.00 V/A
* Default setting dependent on the model.
Current controller parameters for "SLSM-PSM" motor control mode.
0x2942:005
Current controller parameters: d-axis reset time
0.01 ... [3.00]* ... 2000.00 ms
* Default setting dependent on the model.
0x2942:006
Current controller parameters: q-axis gain
0.00 ... [26.00]* ... 750.00 V/A
* Default setting dependent on the model.
0x2942:007
Current controller parameters: q-axis reset time
0.01 ... [3.00]* ... 2000.00 ms
* Default setting dependent on the model.