Inverter motor brake

Parameter
Address
Name / setting range / [default setting]
Information
0x2541:004
Brake energy management: Additional frequency
0.0 ... [0.0] ... 10.0 Hz
Frequency deviation which is connected to the deceleration ramp in a pulsative fashion when the "Inverter motor brake" braking method is used.