Safety-related characteristics Extended Safety
|
Basics of the safety-related characteristics
|
||||
|
|
|
Source of failure rates
|
SN 29500
|
When no values from the component manufacturers were available.
|
|
Average max. ambient temperature
|
60 °C
|
|
||
|
Extended Safety - S and Extended Safety - ST
|
||||
|
|
EN IEC 61508, part 1-7
EN 62061 |
Safety Integrity Level
|
SIL 3
|
|
|
PFH [1/h]
|
< 1 E-09
|
< 1% of SIL 3
|
||
|
PFDavg (T)
|
< 1 E-04
|
< 10% of SIL 3 after T = 20 years
|
||
|
Proof test interval T
|
20 years
|
Mission time
|
||
|
EN ISO 13849-1
|
Category
|
4
|
|
|
|
Performance Level
|
e
|
|
||
|
MTTFd
|
High
|
> 130 years
|
||
|
Mean diagnostic coverage DCavg
|
High
|
95%
|
||
|
Extended Safety - ST (safe single-channel inputs)
The safety-related parameters of the safe single-channel inputs differ due to their SIL 2 classification.
|
||||
|
|
EN IEC 61508, part 1-7
EN 62061 |
Safety Integrity Level
|
SIL 2
|
|
|
PFH [1/h]
|
< 2 E-08
|
< 1% of SIL 2
|
||
|
PFDavg (T)
|
< 1.5 E-03
|
< 10% of SIL 2 after T = 20 years
|
||
|
Proof test interval T
|
20 years
|
Mission time
|
||
|
EN ISO 13849-1
|
Category
|
2
|
|
|
|
Performance Level
|
c
|
|
||
|
MTTFd
|
High
|
> 40 years
|
||
|
Mean diagnostic coverage DCavg
|
High
|
95%
|
||
Further data and information can be found in the corresponding project planning document in the "Electrical installation" chapter.