Triggering STO via the safety bus
|
tPLC + tBUS,CYL + tBUS,OUT + tIMP
|
|
tPLC + tBUS,CYL + (108, 16 or 32 ms) + 6 ms
|
|
STO status flag feedback via safety bus
|
tPLC + tBUS,CYL + tBUS,OUT + tI + tBUS,IN + tPLC
|
|
tPLC + tBUS,CYL + (108, 16 or 32 ms) + 4 ms + (40, 8 or 20 ms) + tPLC
|
|
Triggering STO via a safe input
|
tSEN + tIN + tI + tIMP
|
|
tSEN + (0 ... 100 ms) + 2 ms + 4 ms + 6 ms
|
|
Triggering the safe output via the safety bus
|
tPLC + tBUS,CYL + tBUS,OUT + tOUT + tAK
|
|
tPLC + tBUS,CYL + (108, 16 or 32 ms) + 4 ms + tAK
|
|
Transmission of the safe input to the safety PLC
|
tSEN + tIN + tBUS,IN + tBUS,CYL + tPLC
|
|
tSEN + (0 ... 100 ms) + (40, 8 or 20 ms) + tBUS,CYL + tPLC
|
|
Triggering STO via a safe input and feeding back the STO status flag to the safety PLC
|
STO trigger: tSEN + tIN + tI + tIMP
|
|
STO trigger: tSEN + (0 ... 100 ms) + 4 ms + 6 ms
|
|
STO status flag: tSEN + tIN + tI + tBUS,IN + tBUS,CYL + tPLC
|
|
STO status flag: tSEN + (0 ... 100 ms) + 4 ms + (40, 8 or 20 ms) + tBUS,CYL + tPLC
|