Response times of the safety unit

For the calculation of the response time to the request of a safety function, the overall system must be taken into account:
–
Response time of the connected safety sensors.
 
–
Internal processing time.
 
–
Deceleration times, braking times, and stop times from the parameterized safety functions.
 
–
Safety bus:
 
–
Monitoring time for cyclic services.
 
–
Monitoring time in the safety PLC.
 
–
Processing time in the safety PLC
 
 
–
Deceleration times due to further components.
 
 
–
Information on how to calculate the processing time and transmission time of the safety bus can be found in the documentation of the safety PLC used.
 
–
Include the times of the safety functions in the calculation, e.g. for SS1 the stop time until STO is active.
 
 
 
Response times for the "Extended Safety" version
1
Basic device 
 
2
Integrated safety 
 
3
Safety PLC 
 
4
Safety bus 
 
SF
Triggered safety function 
 
 
Response times of safety modules
tI
Processing time of the integrated safety
(taking into account the feedback from the status flags for the input)
4 ms
tSEN
Response time of the safety sensors
See manufacturer information
tIN
Input delay of the safe inputs
Parameterizable via 0x211A:001, 0x211A:002, 0x211A:016 ... 0x211A:019
0 ... 100 ms
Input filter
2 ms
tBUS,IN
Sending a safety telegram to the safety PLC
PROFIsafe
40 ms
FSoE
8 ms
CIP Safety
20 ms
tBUS,OUT
Receiving a safety telegram from the safety PLC
PROFIsafe
108 ms
FSoE
16 ms
CIP Safety
32 ms
tOUT
Delay in safe output
4 ms
tAK
Time until the safety actuators have shut down.
See manufacturer information
tBUS,CYL
Safety bus cycle time
PROFIsafe
See "Project Planning" in the Safety PLC
FSoE
CIP Safety
tPLC
Cycle time of the safety PLC
See the manufacturer's specifications for the safety PLC
tIMP
Time delay of the safe pulse inhibit
6 ms
Response times of a function
Triggering STO via the safety bus
tPLC + tBUS,CYL + tBUS,OUT + tIMP
tPLC + tBUS,CYL + (108, 16 or 32 ms) + 6 ms
STO status flag feedback via safety bus
tPLC + tBUS,CYL + tBUS,OUT + tI + tBUS,IN + tPLC
tPLC + tBUS,CYL + (108, 16 or 32 ms) + 4 ms + (40, 8 or 20 ms) + tPLC
Triggering STO via a safe input
tSEN + tIN + tI + tIMP
tSEN + (0 ... 100 ms) + 2 ms + 4 ms + 6 ms
Triggering the safe output via the safety bus
tPLC + tBUS,CYL + tBUS,OUT + tOUT + tAK
tPLC + tBUS,CYL + (108, 16 or 32 ms) + 4 ms + tAK
Transmission of the safe input to the safety PLC
tSEN + tIN + tBUS,IN + tBUS,CYL + tPLC
tSEN + (0 ... 100 ms) + (40, 8 or 20 ms) + tBUS,CYL + tPLC
Triggering STO via a safe input and feeding back the STO status flag to the safety PLC
STO trigger: tSEN + tIN + tI + tIMP
STO trigger: tSEN + (0 ... 100 ms) + 4 ms + 6 ms
STO status flag: tSEN + tIN + tI + tBUS,IN + tBUS,CYL + tPLC
STO status flag: tSEN + (0 ... 100 ms) + 4 ms + (40, 8 or 20 ms) + tBUS,CYL + tPLC