0x2024:002
|
Special settings: Configure STO
0 ... [0] ... 65535
–
Setting can only be changed if the inverter is disabled.
|
Different drive behaviour with reference to the CiA402 state machine.
|
|
Bit 0
|
Activate STO locked
|
0 = After "STO active", the inverter is in the "Ready to switch on [4]" device status.
1 = After "STO active", the inverter is in the "Switch on disabled [3]" device status.
In order to restart the inverter from this device state, the following conditions must be met:
–
No STO activation AND
–
Transition (FALSE ↗ TRUE) of the configured start signal
0 = standard behavior: After STO is activated, the device status changes to “Switched on”.
1 = Behavior as with the i700 servo inverter: After STO is activated, the device status changes to “Switch-on disabled”.
|
|
0x2024:003
|
Special settings: STO reaction
|
Selection of the response to STO.
–
With the "No response" setting, no logging takes place in the logbook. This setting is useful if STO is used as a valid stop method for normal operation in order to limit the number of entries in the logbook.
Associated event ID:
–
65285 | 0xFF05 - Safe torque off (STO) activated
|
|
0
|
No response
|
|
|
11
|
Information
|
|
12
|
Warning
|
|
0x2890
|
STO Source SD-In
–
Safety parameter (Safety parameter list)
|
Selection of a safe input as a trigger source for the function.
|
|
0
|
Disabled
|
|
|
1
|
SD-In1
|
|
2
|
SD-In2
|
|
16
|
SD-In1-A
|
|
17
|
SD-In1-B
|
|
18
|
SD-In2-A
|
|
19
|
SD-In2-B
|
|
0x2891
|
STO Source S-Bus
–
Safety parameter (Safety parameter list)
|
Selection of the safety bus as the trigger source for the function.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x2892:001
|
STO: Restart
–
Safety parameter (Safety parameter list)
|
Restart behavior after the function has been canceled.
|
|
0
|
Acknowledged restart
|
|
|
1
|
Automatic restart
|
|
0x2893
|
STO "STO active" - Output
–
Safety parameter (Safety parameter list)
|
Selection of the safe output for the "STO active" feedback.
|
|
0
|
Disabled
|
|
|
1
|
SD-Out1 positive logic
|
|
2
|