Setting
Adapt the restart to your application.
 
 
DANGER!
If the setting 0x2892:001 = 1, an automatic restart takes place when the request for the safety function is canceled.
Possible consequences: Death or severe injuries
▶
You must provide external measures according to EN ISO 13849-1 which ensure that the drive only restarts after a confirmation.
 
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2024:002
Special settings: Configure STO
0 ... [0] ... 65535
–
Setting can only be changed if the inverter is disabled.
 
Different drive behaviour with reference to the CiA402 state machine.
Bit 0
Activate STO locked
0 = After "STO active", the inverter is in the "Ready to switch on [4]" device status.
1 = After "STO active", the inverter is in the "Switch on disabled [3]" device status.
In order to restart the inverter from this device state, the following conditions must be met:
–
No STO activation AND
 
–
Transition (FALSE
↗
TRUE) of the configured start signal
 
0 = standard behavior:
After STO is activated, the device status changes to “Switched on”.
1 = Behavior as with the i700 servo inverter:
After STO is activated, the device status changes to “Switch-on disabled”.
0x2024:003
Special settings: STO reaction
Selection of the response to STO.
–
With the "No response" setting, no logging takes place in the logbook. This setting is useful if STO is used as a valid stop method for normal operation in order to limit the number of entries in the logbook.
 
Associated event ID:
–
65285 | 0xFF05 - Safe torque off (STO) activated
 
0
No response
11
Information
12
Warning
0x2890
STO Source SD-In
–
Safety parameter (Safety parameter list)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
16
SD-In1-A
17
SD-In1-B
18
SD-In2-A
19
SD-In2-B
0x2891
STO Source S-Bus
–
Safety parameter (Safety parameter list)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x2892:001
STO: Restart
–
Safety parameter (Safety parameter list)
 
Restart behavior after the function has been canceled.
0
Acknowledged restart
1
Automatic restart
0x2893
STO "STO active" - Output
–
Safety parameter (Safety parameter list)
 
Selection of the safe output for the "STO active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic