Node address setting

Each network node must be provided with a unique node address.
 
–
The node address of the inverter can be optionally set in 0x2321:001 (P510.01) or using the DIP switches on the device labelled with "1" ... "128".
 
–
The setting that is active when the inverter is switched on is the effective setting.
 
–
The labelling of the DIP switches corresponds to the values of the individual DIP switches for determining the node address (see the following example).
 
–
The node address 0 is reserved for messages to all nodes ("Broadcast") .
 
–
The active node address is shown in 0x2322:001 (P511.01).
 
 
Example of how the node address is set via the DIP switches
DIP switch
128
64
32
16
8
4
2
1
Setting
OFF
OFF
OFF
ON
OFF
ON
ON
ON
Value
0
0
0
16
0
4
2
1
Node address
= sum of all values = 16 + 4 + 2 + 1 = 23
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2321:001
(P510.01)
Modbus settings: Node ID
(Modbus sett.: Node ID)
1 ... [1] ... 247
Optionally setting of the node address (instead of setting via DIP switches 1 ... 128).
–
The node address set here only becomes effective if DIP switches 1 ... 128 have been set to OFF before mains switching.
 
–
A change in the node address only becomes effective after a restart of Modbus communication.