Expert settings

Parameter
Address
Name / setting range / [default setting]
Information
0x2C11:001
High speed range: Lower limit
10 ... [20] ... 100 %
Definition of the lower limit of the high speed range.
–
The lower limit has a permanent hysteresis of 5 %.
 
0x2C11:002
High speed range: Tracking controller gain
0 ... [250] ... 65535 %
Gain factor for tracking the rotor position in the motor model.
0x2C11:003
High speed range: Tracking controller reset time
0.00 ... [6.00] ... 655.35 ms
Reset time for tracking the rotor position in the motor model.
0x2C11:004
High speed range: Tracking controller decouple time
0.00 ... [0.00] ... 655.35 ms
Temporal hysteresis for the switching back and forth from the open-loop controlled to the closed-loop controlled operation.
0x2C12:001
SM low speed range: Acceleration current
0 ... [100] ... 400 %
R.m.s. current value for acceleration processes in the lower velocity range.
–
100 % = Rated motor current (0x6075)
 
–
In the lower speed range and during the acceleration phase, the current setpoints of 0x2C12:001 and 0x2C12:002 are added and injected to the motor.
 
0x2C12:002
SM low speed range: Standstill current
0 ... [20] ... 400 %
R.m.s. current value for processes without acceleration (for instance standstill or constant setpoint speed) in the lower velocity range.
–
100 % = Rated motor current (0x6075)
 
–
In the lower speed range and during the acceleration phase, the current setpoints of 0x2C12:001 and 0x2C12:002 are added and injected to the motor.
 
Note!
At the "100 %" setting, a motor current flows at standstill and at constant speed. The r.m.s. value of this motor current
is greater than the rated motor current by a factor of sqrt(2) at standstill. The reason for this is that a DC current is injected into the synchronous motor at a standstill. The correct rated motor current flows when the motor turns.