Manual setting of the motor data

There are two options to parameterize a motor.
1. Enter nameplate data
Enter the following motor data:
0x2C01:001Number of pole pairs
0x2C01:002Stator resistance
0x2C01:003Stator leakage inductance
0x2C01:004 Rated speed
0x2C01:005Rated frequency
0x2C01:006Rated power
0x2C01:007Rated voltage
0x2C01:008Cosine phi
0x2C01:009Insulation class
0x6075Rated motor current
When you touch the "Estimate" button in the engineering tool, more parameters depending on the motor are shown.
 
2. Enter data of the motor data sheet
The motor data and the parameters depending on the motor are entered. The parameters mentioned under 1. are the following:
0x2D4C:001 Thermal time constant of the winding
0x2D4C:002 Thermal time constant - laminated core
0x2D4C:003 Influence of winding
0x2D4C:004 Starting value
0x6076Rated motor torque
Additionally for ASM:
0x2C02:001Rotor resistance
0x2C02:002Mutual inductance
0x2C02:003Magnetizing current
Additionally for PSM:
0x2C03:001 EMF constant
0x2C03:002 Resolver pole position
0x2C03:003Temperature coefficient magnets (kTN)
0x2C03:004Encoder pole position
 
After the motor data has been parameterized via one of the two options, the following monitoring and limit values are initialized with motor-dependent preset values by touching the "Initialize" button:
0x2D44:001 Overspeed monitoring threshold
0x2D46:001 Overcurrent monitoring threshold
0x2D49:003 Motor temperature monitoring warning threshold
0x2D49:004 Motor temperature monitoring error threshold
0x6073 Maximum current
0x6075Rated motor current
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2822:037
Axis commands: Estimate all motor parameters based on rated data
0
Off/Ready
1
On/Start
2
In progress
3
Action cancelled
4
No access
5
No access (controller inhibit)
0x2822:038
Axis commands: HIPERFACE (A): Set position with synchronization
0
Off/Ready
1
On/Start
2
In progress
3
Action cancelled
4
No access
5
No access (controller inhibit)
0x2C01:001
Motor parameters: Number of pole pairs
–
Read only
 
Display of the number of pole pairs calculated from the rated speed and rated frequency.
0x2C01:002
Motor parameters: Stator resistance
0.0000 ... [13.5000] ... 125.0000 Ω
General motor data.
Carry out settings as specified by manufacturer data/motor data sheet.
 
Note!
When you enter the motor nameplate data, take into account the phase connection implemented for the motor (star or delta connection). Only enter the data applying to the connection type selected.
0x2C01:003
Motor parameters: Stator leakage inductance
0.000 ... [51.000] ... 500.000 mH
0x2C01:004
Motor parameters: Rated speed
0 ... [4050] ... 50000 rpm
General motor data.
Carry out settings as specified by motor nameplate data.
 
Note!
When you enter the motor nameplate data, take into account the phase connection implemented for the motor (star or delta connection). Only enter the data applying to the connection type selected.
0x2C01:005
Motor parameters: Rated frequency
0.0 ... [270.0] ... 2000.0 Hz
0x2C01:006
Motor parameters: Rated power
0.00 ... [0.25] ... 655.35 kW
0x2C01:007
Motor parameters: Rated voltage
0 ... [225] ... 65535 V
0x2C01:008
Motor parameters: Cosine phi
0.00 ... [0.80] ... 1.00
0x2C01:009
Motor parameters: Insulation class
Insulation class of the motor (see motor nameplate).
0
Y (cut-off temperature = 90 °C)
1
A (cut-off temperature = 105 °C)
2
E (cut-off temperature = 120 °C)
3
B (cut-off temperature = 130 °C)
4
F (cut-off temperature = 155 °C)
5
H (cut-off temperature = 180 °C)
6
G (cut-off temperature > 180 °C)
0x2C02:001
Motor parameter (ASM): Rotor resistance
0.0000 ... [0.0000] ... 214748.3647 Ω
Equivalent circuit data required for the motor model of the asynchronous machine.
0x2C02:002
Motor parameter (ASM): Mutual inductance
0.0 ... [0.0] ... 214748364.7 mH
0x2C02:003
Motor parameter (ASM): Magnetising current
0.00 ... [0.00] ... 500.00 A
0x2C03:001
Motor parameter (PSM): Back EMF constant
0.0 ... [41.8] ... 100000.0 V/1000rpm
Voltage induced by the motor (rotor voltage / 1000 rpm).
For permanently excited synchronous motors, the e.m.f. constant describes the r.m.s. value of the line-to-line voltage (phase voltage) induced in idle state by the motor (reference: 1000 rpm, 20 °C).
Measured: Line to Line (L - L)
0x2C03:002
Motor parameter (PSM): Resolver pole position
-179.9 ... [-90.0] ... 179.9 °
Equivalent circuit data required for the motor model of the synchronous machine.
0x2C03:003
Motor parameter (PSM): Magnets temperature coefficient (kTN)
-1.000 ... [-0.110] ... 0.000 %/°C
0x2C03:004
Motor parameter (PSM): Encoder pole position
-179.9 ... [0.0] ... 179.9 °
0x2D4C:001
Thermal model motor utilization (i²xt): Motor utilisation (i²xt)
1 ... [60] ... 36000 s
Setting of the time constant for the winding.
0x2D4C:002
Thermal model motor utilization (i²xt): Thermal time constant - laminations
1 ... [852] ... 36000 s
Setting of the time constant for the laminated core.
0x2D4C:003
Thermal model motor utilization (i²xt): Winding influence
0 ... [27] ... 100 %
Part of the thermal motor model: distribution factor of the copper winding influence.   
0x6072
Max. torque
0.0 ... [250.0] ... 3276.7 %
0x6073
Max. current
0.0 ... [150.0] ... 3276.7 %
Max. current of the inverter.
Associated event ID:
–
537469829 | 0x20092385 - Parameterized max. motor current > max. device current
 
0x6075
Rated motor current
0.001 ... [1.300] ... 1000.000 A
–
Setting can only be changed if the inverter is disabled.
 
The rated motor current that needs to be set here serves as a reference value for different parameters that involve a setting for/display of a current value in percent.
Example:
–
Rated motor current = 1.7 A
 
–
Max. current 0x6073 = 200 %
Rated motor current = 3.4 A
 
0x6076
Rated motor torque
0.001 ... [0.600] ... 100000.000 Nm
–
Setting can only be changed if the inverter is disabled.
 
The rated motor torque to be set here serves as a reference value for different parameters with a setting/display of a torque value in percent.
Example:
–
Rated motor torque = 1.65 Nm
 
–
Max. torque 0x6072 = 250 % Rated motor torque = 4.125 Nm
 
0x6080
Max. motor speed
0 ... [6075] ... 480000 rpm
Limitation of the max. motor speed. Depending on the parameter setting of 0x2D44:001 (Overspeed monitoring: threshold), the speed limitation (0x6080 / Max. motor speed) may become active before speed monitoring.