Motor speed monitoring
This function monitors the motor speed during operation.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
0x2D44:001
|
Overspeed monitoring: Threshold
5 ... [8000] ... 50000 rpm
|
|
|
0x2D44:002
|
Overspeed monitoring: Response
|
Selection of the response to the triggering of motor speed monitoring.
|
|
0
|
No response
|
|
|
1
|
Warning
|
|
|
2
|
Trouble
|