Logbook
With the logbook, the controller has access to the last 32 messages of the inverter.
–
The logbook is saved persistently in the inverter.
–
The logbook has a ring buffer structure:
–
As long as free memory is available in the logbook, a message is entered following the next free memory unit.
–
When all memory units are occupied, the oldest message is deleted for a new message.
–
Always the most recent messages remain available.
–
On the basis of the "Diag code" (32-bit word) of each individual message it can be seen which axis the message refers to.
Preconditions
The logbook can only be accessed
–
via the user interface of »EASY Starter« ("Diagnostics" tab) or
–
via network.
Details
In contrast to the error history buffer, the logbook additionally protocols the following events:
–
Fault messages
–
Change-over from normal to setup mode (and vice versa)
–
Execution of device commands
–
Avoidance of safety functions
The logbook entries are saved persistently in the inverter. If all 32 memory units are occupied, the oldest entry is deleted for a new entry. By means of the "Delete logbook" device command, all logbook entries can be deleted.
The logbook always displays only one active safety event.
Only when the cause of the safety event has been eliminated and the safety event has been acknowledged, the logbook will display the next safety event that is still active.
Accessing the logbook with »EASY Starter«
1.
Select the inverter on the left side in the »EASY Starter« device list.
2.
Change to the "Diagnostics" tab.
3.
Click the icon to open the logbook.
Observe that the logbook only presents a snapshot at the time the data is read out. If a new event occurs, the logbook must be read out again so that the new event becomes visible.
Accessing the logbook via network
The logbook can also be accessed via network from a higher-level controller or a visualisation. The structure of the diagnostic messages complies with the "ETG.1020" standard of the EtherCAT Technology Group (ETG).
See chapter 13.3 of document "ETG.1020 Protocol Enhancements" provided by the EtherCAT Technology Group (ETG) for detailed information on the structure of the diagnostic messages.
Parameter
to open the logbook.