Diagnostic parameters

The inverter provides many diagnostic parameters which are helpful for operation, maintenance, error diagnosis, error correction, etc.
 
–
The following overview lists the most common diagnostic parameters.
 
–
Further parameters for more specific diagnostic purposes are described in the following subchapters.
 
–
The diagnostic parameters can only be read and cannot be written to.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2030
CRC parameter set
–
Read only
 
0x2B0B
Ramp generator frequency
–
Read only: x.x Hz
 
Display of the current frequency setpoint. The frequency setpoint is internally transferred to the motor control (based on scaling and ramp generator).
0x2D4F
Motor utilisation (i²xt)
–
Read only: x %
 
Display of the current thermal motor utilisation.
0x2DA2:001
Output power: Effective power
–
Read only: x.xxx kW
 
Display of the active output power for an energy analysis in the respective application.
0x2DA3:003
Output energy: Overall energy
-21474836.47 ... [0.00] ... 21474836.47 kWh
Display of the energy balance:
–
Positive values: Energy consumed
 
–
Negative values: Generated energy
 
0x2DA3:003 = 0 resets the energy balance.
When replacing a device, the value of the old device can be adopted as the starting value for the new device.
0x2DD0:001
Field values: Actual value
–
Read only: x %
 
Display of the actual current flow value.
0x2DD0:002
Field values: Setpoint value
–
Read only: x %
 
Display of the setpoint flow value.
0x2DD1:001
Motor currents: Actual D-current (id)
–
Read only: x.xx A
 
Display of the actual D current.
0x2DD1:002
Motor currents: Actual Q-current (iq)
–
Read only: x.xx A
 
Display of the actual Q current.
0x2DD1:003
Motor currents: Setpoint D-current (id)
–
Read only: x.xx A
 
Display of the setpoint D current.
0x2DD1:004
Motor currents: Setpoint Q-current (iq)
–
Read only: x.xx A
 
Display of the setpoint Q current.
0x2DD1:005
Motor currents: Motor current (Ieff)
–
Read only: x.xx A
 
Display of the effective motor current.
0x2DD2
Target position interpolated
–
Read only
 
Display of the interpolated position setpoint.
0x2DD3:001
Speed setpoints: Speed setpoint
–
Read only: x rpm
 
Display of the speed setpoint value 1.
0x2DD3:002
Speed setpoints: Speed setpoint 2
–
Read only: x rpm
 
Display of the speed setpoint value 2.
0x2DD3:003
Speed setpoints: Speed setpoint limited
–
Read only: x rpm
 
Display of the limited speed setpoint.
0x2DD4:001
Speed controller output signals: Output signal 1
–
Read only: x.x %
 
Display of the output signal 1 from the speed controller.
0x2DD4:002
Speed controller output signals: Output signal 2
–
Read only: x.x %
 
Display of the output signal 2 from the speed controller.
0x2DD6:001
Torque filter cascade: Starting value
–
Read only: x.x %
 
Display of the start value.
0x2DD6:002
Torque filter cascade: Notch filter 1 input value
–
Read only: x.x %
 
Display of the input value for notch filter 1.
0x2DD6:003
Torque filter cascade: Notch filter 2 input value
–
Read only: x.x %
 
Display of the input value for notch filter 2.
0x2DD6:004
Torque filter cascade: Torque setpoint filtered
–
Read only: x.x %
 
Display of the filtered torque setpoint value.
0x2DD7:001
Voltage values: Actual voltage (motor voltage limit)
–
Read only: x.x V
 
Display of the current motor voltage limit.
0x2DD7:002
Voltage values: Output signal D current controller
–
Read only: x.x V
 
Display of the output voltage of the D-current controller.
0x2DD7:003
Voltage values: Output signal Q current controller
–
Read only: x.x V
 
Display of the output voltage of the Q-current controller.
0x2DD7:004
Voltage values: D voltage (magnetisation)
–
Read only: x.x V
 
Display of the D-voltage (magnetisation).
0x2DD7:005
Voltage values: Q voltage (torque)
–
Read only: x.x V
 
Display of the Q-voltage (torque).
0x2DD7:006
Voltage values: Phases U-V
–
Read only: x.x V
 
Display of the actual voltage phase U - phase V.
0x2DD7:007
Voltage values: Phases V-W
–
Read only: x.x V
 
Display of the actual voltage phase V - phase W.
0x2DD7:008
Voltage values: Phases W-U
–
Read only: x.x V
 
Display of the actual voltage phase W - phase U.
0x2DD7:009
Voltage values: Phase U
–
Read only: x.x V
 
Display of the actual voltage of phase U.
0x2DD7:010
Voltage values: Phase V
–
Read only: x.x V
 
Display of the actual voltage of phase V.
0x2DD7:011
Voltage values: Phase W
–
Read only: x.x V
 
Display of the actual voltage of phase W.
0x2DDC
Actual slip value
–
Read only: x.x Hz
 
Display of the actual slip.
0x2DDD
Output frequency
–
Read only: x.x Hz
 
Display of the current output frequency of the inverter.
0x2DDE
Actual rotor angle position
–
Read only
 
Display of the actual position of the rotor angle.
0x2DDF:001
Axis information: Rated current
–
Read only: x.xx A
 
Display of the rated current of the axis.
0x2DDF:002
Axis information: Maximum current
–
Read only: x.xx A
 
Display of the maximum current of the axis.
Associated event ID:
–
537469829 | 0x20092385 - Parameterized max. motor current > max. device current
 
0x2DE0:006
Service settings: OEM service Data - SN
–
Read only
 
Display of OEM service data.
0x6077
Actual torque
–
Read only: x.x %
 
Display of the actual torque.
–
100 % = Rated motor torque 0x6076
 
0x6078
Actual current
–
Read only: x.x %
 
Display of the motor actual current.
–
100 % =  Rated motor current 0x6075
 
0x6079
DC-bus voltage
–
Read only: x.xxx V
 
Display of the current DC-bus voltage.