Process input data (CiA 402 objects)

Parameter
Address
Name / setting range / [default setting]
Information
0x6060
CiA: Operation mode
CiA: Operation mode
-13
MS: Manual jog open loop (MOL)
Manufacturer-specific manual control
-12
MS: Pole position identification (PPI)
Manufacturer-specific pole position identification (PLI)
0
No selection
No selection
2
CiA: Velocity mode (vl)
8
CiA: Cyclic sync position (csp)
9
CiA: Cyclic sync velocity mode (csv)
10
CiA: Cyclic sync torque mode (cst)
0x607A
Set position
-2147483648 ... [0] ... 2147483647
Setting of the set position.
0x60B1
Offset speed
-2147483648.00 ... [0.00] ... 2147483647.00 rpm
Additive value for setpoint velocity or velocity feedforward control - offset speed.
0x60B2
Offset torque
-3276.8 ... [0.0] ... 3276.7 %
Offset torque
–
100 % 
=
 rated motor power (0x6076)
 
0x60E0
Positive torque limit
0.0 ... [100.0] ... 3276.7 %
Positive torque limit source for speed control with torque limitation.
–
100 % = Rated motor torque 0x6076
 
0x60E1
Negative torque limit
0.0 ... [100.0] ... 3276.7 %
Negative torque limit source for speed control with torque limitation.
–
100 % = Rated motor torque 0x6076