Monitoring the position error

Position error monitoring can be used for the following control modes:
–
Servo control for synchronous motor (SM), 0x2C00 = [1]
 
–
Servo control for asynchronous motor (ASM), 0x2C00 = [2]
 
Following error monitoring is effective in an operating mode with position controller. The system deviation (i. e. the following error) is compared to the following error tolerance set at the input of the position controller (see red arrow in the figure below).
The error response set in 0x2D51:006 is executed if ...
1.
the following error tolerance set in 0x2D51:004 is exceeded and ...
 
2.
the exceedance lasts at least as long as set in 0x2D51:005.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2D51:004
Position error/speed error - monitoring: Position error - error threshold
1 ... [360] ... 2147483647 °
Setting of the error threshold for position error monitoring.
0x2D51:005
Position error/speed error - monitoring: Position error - min. time for error
0 ... [0] ... 50 ms
Setting of the minimum time a position error must be pending until an error/warning message is triggered.
0x2D51:006
Position error/speed error - monitoring: Position error - error response
Setting of the error response of position error monitoring.
0
No response
1
Fault > CiA402
2
Warning
0x2922:001
Following error diagnostics: Following error (interval) - Time
10 ... [1000] ... 65535 ms
Time interval for determining the following error.
0x2922:002
Following error diagnostics: Following error (interval) - Mean value
–
Read only: x.xx °
 
Mean value in the time interval
0x2922:003
Following error diagnostics: Following error (interval) - Maximum value
–
Read only: x.xx °
 
Maximum value in the time interval
0x2922:004
Following error diagnostics: Following error (manual) - Start/Stop
Determination of the following error between manually specified start/stop command.
0
Stop
1
Start
0x2922:005
Following error diagnostics: Following error (manual) - Mean value
–
Read only: x.xx °
 
Mean value between "start" and "stop"
0x2922:006
Following error diagnostics: Following error (manual) - Maximum value
–
Read only: x.xx °
 
Maximum value between "start" and "stop"
0x2922:007
Following error diagnostics: Following error (standstill-standstill) - Mean value
–
Read only: x.xx °
 
Mean value between "standstill" and "standstill" of the drive (< 5 rpm)
The value is automatically updated when the speed drops below 5 rpm again.
0x2922:008
Following error diagnostics: Following error (standstill-standstill) - Maximum value
–
Read only: x.xx °
 
Maximum value between "standstill" and "standstill" of the drive (< 5 rev./min)
The value is automatically updated when the speed drops below 5 rpm again.