0x2114:001
|
Parameter set: Version
–
Safety parameter (+Safety parameter list+)
|
Display of the version of the safe parameter set.
|
|
10301
|
i750 ES V1.3
|
|
|
0x2114:002
|
Parameter set: Project CRC
0 ... [0] ... 4294967295
–
Safety parameter (+Safety parameter list+)
|
Project CRC of the safe parameter set.
|
|
0x2115:001
|
Parameter set: Status
–
Read only
–
Safety parameter (+Safety parameter list+)
|
Current status of the safe parameter set.
|
|
0
|
No parameter set
|
|
|
1
|
Valid parameter set
|
|
4
|
CRC error
|
|
5
|
Version error
|
|
7
|
Plausibility error
|
|
8
|
Assignment error
|
|
9
|
Local read error
|
|
10
|
Communication error with basic device
|
|
11
|
Faulty release
|
|
12
|
Different CRCs
|
|
13
|
Changed parameter set
|
|
14
|
Parameter set checked
|
|
15
|
Parameter set check active
|
|
0x2115:002
|
Parameter set: Current CRC
–
Read only
–
Safety parameter (+Safety parameter list+)
|
Display of the current parameter CRC from the safe parameter set.
|
|
0x2115:003
|
Parameter set: Last valid CRC
–
Read only
–
Safety parameter (+Safety parameter list+)
|
Display of the last valid parameter set CRC.
|
|
0x2115:004
|
Parameter set: Parameter setting time stamp
–
Read only: x s
–
Safety parameter (+Safety parameter list+)
|
Time when the parameter set is taken over from the device as the value of the power-on time meter.
|
|
0x2115:005
|
Parameter set: Error information 1
–
Read only
–
Safety parameter (+Safety parameter list+)
|
Error number in case of a plausibility error. 0x2115:001 = 7
|
|
0x2115:006
|
Parameter set: Error information 2
–
Read only
–
Safety parameter (+Safety parameter list+)
|
Reserved
|
|
0x2115:007
|
Parameter set: Error information 3
–
Read only
–
Safety parameter (+Safety parameter list+)
|
|
0x2115:008
|
Parameter set: Current CRC without safety address
–
Read only
–
Safety parameter (+Safety parameter list+)
|
Display of the current parameter CRC from the safe parameter set without safety address.
|