Safety - Parameter set plausibility errors
The following table contains the detailed information about the possible plausibility errors.
The error code corresponds to the entry in 0x2115:005.
|
Error information 1
|
Error in the setting of the safe parameterization
|
|
|
|
|
12
|
If SS1 is parameterized so that STO is triggered after reaching n = 0, the delay time "STO after n = 0" must be zero.
|
|
27
|
If muting (MUT) is parameterized, a password must be assigned.
|
|
29
|
If the S-Bus is to be hidden via muting (MUT), an S-Bus must also be parameterized.
|
|
Error information 1
|
Error in the setting of the safe parameterization
|
|
|
|
|
6
|
If no motor encoder is parameterized, no function requiring an encoder may be parameterized.
|
|
8
|
If a resolver is parameterized as motor encoder, max. 10000 rpm divided by the number of pole pairs of the resolver may be set as speed value due to the system.
|
|
9
|
If SS1 is parameterized so that STO is triggered after reaching n = 0, the delay time "STO after n = 0" must be less than or equal to the stopping time.
|
|
12
|
If no motor encoder system is parameterized, the delay time "STO after n = 0" must be zero.
|
|
13
|
The lower position limit for PDSS must be less than or equal to the upper position limit for PDSS.
|
|
14
|
The lower SCS limit for PDSS must be less than or equal to the upper SCS limit.
|
|
15
|
The lower position limit for SLP must be less than or equal to the upper position limit for SLP.
|
|
16
|
The lower position limit for SCA must be less than or equal to the upper position limit for SCA.
|
|
19
|
If the input source for SHom_Start is deactivated, no function based on an absolute position may be parameterized.
|
|
27
|
If muting (MUT) is parameterized, a password must be assigned.
Valid from safety parameter set V1.1.
|
|
29
|
If the S-Bus is to be hidden via muting (MUT), an S-Bus must also be parameterized.
Valid from safety parameter set V1.1.
|