Functional description
SS1-r (STO after stop time)
–
If the SS1-r stop function is activated, a monitoring ramp is calculated and placed over the deceleration ramp in the application.
–
SS1-r activates the normal stop STO when the parameterized stop time has elapsed and the monitoring ramp has not been exceeded.
–
If standstill has not yet been reached, the motor coasts down.
SS1-r (STO at standstill)
–
If the SS1-r stop function is activated, a monitoring ramp is calculated and placed over the deceleration ramp in the application.
–
SS1-r activates the normal stop STO when standstill is detected and the monitoring ramp has not been exceeded.
–
Detection of standstill:
–
For applications without encoder: n ≤ 5 rpm
–
For applications with encoder: n is within the parameterized tolerance window