0x2894:001
|
SS1, SS2: Stopping time
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
|
Monitored stopping time for SS1 and SS2.
Changes only possible in the +Safety parameter list+.
|
|
0x2894:002
|
SS1, SS2: Ramp monitoring
–
Safety parameter (+Safety parameter list+)
|
Selection of whether the deceleration ramp is to be monitored when SS1 and SS2 are executed.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x2894:003
|
SS1, SS2: Ramp - Smoothing time
0 ... [0] ... 100 %
–
Safety parameter (+Safety parameter list+)
|
S-ramp time of the deceleration ramp for SS1 and SS2.
0 % = linear ramp
Changes only possible in the +Safety parameter list+.
|
|
0x2894:004
|
SS1, SS2: Ramp - Offset mode
–
Safety parameter (+Safety parameter list+)
|
Definition of the speed offset at the start of ramp monitoring.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Relativ
|
|
|
1
|
Absolute
|
|
0x2894:005
|
SS1, SS2: Ramp - Start-offset relative
0 ... [5] ... 100 %
–
Safety parameter (+Safety parameter list+)
|
Definition of the speed offset at the start of ramp monitoring.
Changes only possible in the +Safety parameter list+.
|
|
0x2894:006
|
SS1, SS2: Ramp - Start-offset absolute
0 ... [0] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
|
|
0x2894:007
|
SS1, SS2: Ramp - Currently monitored speed
–
Read only: x rpm
–
Safety parameter (+Safety parameter list+)
|
Currently monitored speed value with active ramp monitoring.
|
|
0x2894:008
|
SS1, SS2: Ramp - Minimum difference
–
Read only: x rpm
–
Safety parameter (+Safety parameter list+)
|
Minimum difference between actual speed and monitored ramp.
|
|
0x2896
|
SS1 Source S-Bus
–
Safety parameter (+Safety parameter list+)
|
Selection of the safety bus as the trigger source for the function.
Changes only possible in the +Safety parameter list+.
|
|
0
|
Disabled
|
|
|
1
|
Activated
|
|
0x2897:001
|
SS1: Mode
–
Safety parameter (+Safety parameter list+)
|
Condition at which STO is triggered.
Changes only possible in the +Safety parameter list+.
|
|
0
|
STO after stopping time
|
STO is only processed after the parameterized stopping time has elapsed.
|
|
1
|
STO at n=0
|
STO is already triggered after reaching n=0.
|
|
0x2897:002
|
SS1: Delay STO after n=0
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
|
Delay time after detection of n = 0 until triggering of STO
Only relevant if "SS1 mode" = "STO with n=0" and operation with encoder system.
Changes only possible in the +Safety parameter list+.
|