Functional description
SHom
Sequence of the reference run
1.
The reference run process is started via the defined input source.
2.
The superimposed application must start the reference run. The drive independently takes over the motion control.
3.
The reference run is performed with the set safely limited speed (SLS).
4.
The reference signal "SHom_Load" is expected within the defined "Timeout" period, which adopts the parameterized position value as the "Home Position" when the reference position is passed.
5.
Once the reference point is set, the reference run is ended.
6.
The drive changes to normal operation.
By parameterization it can be set whether the current position is stored non-volatilely when the voltage supply is switched off. If the restart conditions are fulfilled after the voltage supply is switched on again and after a mini reference run, no new reference run is performed.