Setting
The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2110:014
Delete home position
–
Safety parameter (+Safety parameter list+)
 
Command: Deletion of the safe reference in order to set a new reference.
0
Ready
1
Start
2
In progress
3
Action cancelled
4
No access
0x2880:001
SHom_Start: Source
–
Safety parameter (+Safety parameter list+)
 
Selection of the trigger source for the function.
Changes only possible in the +Safety parameter list+.
0
Disabled
13
S-Bus
0x2881:001
SHom_Load: Source
–
Safety parameter (+Safety parameter list+)
 
Selection of the trigger source for the function.
Changes only possible in the +Safety parameter list+.
13
S-Bus
0x2882:001
SHom: Home position
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Setting of the safe home position, which is taken over at SHOM_Load.
It is the absolute reference point for the SLP, SCA and PDSS safety functions.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
0x2882:002
SHom: Timeout
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
The parameterized home mark must be detected within this monitoring time after SHom_Start.
Changes only possible in the +Safety parameter list+.
0x2882:003
SHom: SLS for homing
–
Safety parameter (+Safety parameter list+)
 
Selection of the SLS function that is active during homing.
Changes only possible in the +Safety parameter list+.
3
SLS1
4
SLS2
5
SLS3
6
SLS4
0x2882:004
SHom: Restart condition
–
Safety parameter (+Safety parameter list+)
 
Setting specifying whether safe homing is required after the restart.
Changes only possible in the +Safety parameter list+.
0
Homing required
1
Load saved reference
0x2882:005
SHom: Starting position tolerance
0 ... [0] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
 
Permitted tolerance between the safe position that is saved and the current safe position after restarting.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
Changes only possible in the +Safety parameter list+.
0x2882:006
SHom: Status
–
Read only
 
–
Safety parameter (+Safety parameter list+)
 
Status of the safe reference.
0
No reference
1
SHom active
2
SHom available
3
Mini-homing active
0x2882:007
SHom: Saved position
–
Read only: x incr.
 
–
Safety parameter (+Safety parameter list+)
 
Safe position saved at the last switch-off.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.