Quick stop

The quick stop function is used for stopping the axis and in the event of an error. Whether quick stop is to be activated with a request via the Cia control word, is set in the technology application under the quick stop mode parameter. 0x503F:010
If the quick stop function is active, it is displayed in the status word of the technology application. 0x500D:005 Bit 13
The source for the signal for activating quick stop is set under the Application quick stop source. 0x5020:007
Special features
–
The quick stop function starts with the acceleration "0".
Exception:If the axis is already in the deceleration phase, it is started with the active setpoint acceleration to avoid prolonging the existing braking process.
 
–
Setpoint generation for the quick stop function starts at the actual speed.
 
–
During the deceleration it is changed to the speed-controlled operation.
 
–
After reaching standstill, it is changed to the position control.
 
–
During the stop, no torque reduction is effective.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x500D:048
Application quick stop - deceleration
1.0000000000 ... [655360.0000000000] ... 2147483647.0000000000
0x500D:049
Application quick stop - jerk
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
0x5020:007
Application quick stop source
Selection of the signal source for activating the quick stop.
0
FALSE
1
TRUE
2
Digital input 1
3
Digital input 2
4
Digital input 3
5
Digital input 4
0x503F:010
Quick stop mode
Selection of quick stop mode
0
Inverter quick stop
Quick stop with linear ramp without jerk limitation.
Stop with 0x6085 (Quick stop deceleration)
1
Application quick stop
Quick stop with ramp with jerk limitation.
Stop with the profile parameters:
–
0x500D:048 (Application quick stop - deceleration)
 
–
0x500D:049 (Application quick stop - jerk)
 
0x503F:012
Status Min. Velocity
0.00 ... [25.00] ... 200.00 %