Status signals

Parameter
Address
Name / setting range / [default setting]
Information
0x2DE0:014
Overwrite bit 4 of CiA control word
0
No overwrite
1
Overwrite with FALSE
2
Overwrite with TRUE
0x500D:004
PLCopen status
–
Read only
 
1
ErrorStop
2
Disabled
3
Standstill
4
Stopping
5
DiscMotion
6
SyncMotion
7
ContMotion
8
Homing
10
Service
0x500D:005
Status word
–
Read only
 
Bit  0
Virtual mode active
Bit  1
Axis ready
Bit  2
Axis enabled
Bit  3
Warning active
Bit  4
Error active
Bit  5
Home position detected
Bit  6
Software limit switches enabled
Bit  7
Software limit switch positive
Bit  8
Software limit switch negative
Bit  9
Hardware limit switch positive
Bit  10
Hardware limit switch negative
Bit  11
STO active
Bit  12
Brake opened
Bit  13
Application quick stop active
Bit  14
Limitation active
Bit  16
"Following error" error active
Bit  17
"Following error" error active
Bit  18
Homing active
Bit  19
Homing switch for touch probe reached
Bit  20
Application torque limits
Bit  21
Manual jog active
Bit  22
Standstill active
Bit  23
Set position reached
Bit  24
Software limit switches switched off
Bit  25
0x500D:010
Actual position
–
Read only
 
0x500D:011
Actual velocity
–
Read only
 
0x500D:013
Actual torque
–
Read only: x.xx Nm
 
0x500D:014
Set position
–
Read only
 
0x500D:015
Set velocity
–
Read only
 
0x500D:017
Set torque
–
Read only: x.xx Nm
 
0x500E:005
Status word
–
Read only
 
Bit  1
Encoder ready
Bit  3
Warning active
Bit  4
Error active
Bit  5
Home position detected
Bit  22
Standstill active
0x500E:010
Actual position
–
Read only
 
0x500E:011
Actual velocity
–
Read only
 
0x503E:001
Status signals
–
Read only
 
Bit  4
Homing done
0x503E:002
Velocity actual value Motor
–
Read only: rpm
 
0x503E:003
Motor actual position
–
Read only: x incr.
 
0x503F:012
Status Min. Velocity
0.00 ... [25.00] ... 200.00 %