Hardware limit switches
Connection of the hardware limit switches
The hardware limit switches are assigned to the digital inputs via the Positive hardware limit source and Negative hardware limit source parameters.
The limit switch evaluation responds to a positive edge.
If the limit switch connections for the digital inputs used are to be fail-safe, change the terminal polarity of the corresponding digital inputs.
Fig. 1: “Hardware limit switch” selection
Activate the hardware limit switches
If either of the hardware limit switches is activated (TRUE signal is applied to input), the parameterized error response is executed.
0x500A:104.
0x500A:104. The error message "HWLimitPos" or "HWLimitNeg" is output, irrespective whether the axis rotates and in which direction it moves.
Reset error to retract the limit switch.
After the error has been reset, only travel requests in the opposite direction are possible. Travel requests in the direction of the limit switch are aborted in the event of an error.
Parameter