Setting

Please note when setting the parameters:
–
Safe input SD-In4:
 
–
SD-In4 is used as a cascading input. It can no longer be parameterized as a universal input.
 
–
SD-In4 must be parameterized as an active input.
 
–
SD-In4 must be parameterized as a source for SSE.
 
–
The input delay for SD-In4 must be parameterized ≤ 10 ms.
 
 
–
Safe output SD-Out1:
 
–
SD-Out1 is used as a cascading output. It can no longer be parameterized as a universal feedback output.
 
–
SD-Out1 must not be controlled via the safety bus.
 
 
–
Safe stop emergency (SSE)
 
–
SD-In4 must be parameterized as a source for SSE.
 
–
STO must be parameterized as an emergency stop function.
 
 
–
Restart:
 
–
The restart must be parameterized as “Acknowledged restart”.
 
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2124
CAS Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
4
SD-In4
0x2118:004
SD-In: SD-In4 sensor type
–
Safety parameter (+Safety parameter list+)
 
Configure or deactivate safe input as active or passive input.
0
Input disabled
1
Passive sensor
2
Active sensor
0x2119:004
SD-In: SD-In4 discrepancy time
0 ... [10] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Maximum time within which the two channels of the secure input may be in impermissible states without an error being detected..
0x211A:004
SD-In: SD-In4 input delay
0 ... [0] ... 100 ms
–
Safety parameter (+Safety parameter list+)
 
Delay time between the detection of the signal change at the safe input and the effective evaluation of the input signal.
0x28A1
SSE Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28A3:001
SSE: Emergency stop function
–
Safety parameter (+Safety parameter list+)
 
Selection of the stop function for emergency stop.
0
STO
1
SS1
0x2892:001
STO: Restart
–
Safety parameter (+Safety parameter list+)
 
Restart behavior after the function has been canceled.
0
Acknowledged restart
1
Automatic restart
0x2125:001
CAS: Stop delay
–
Read only: x ms
 
Delay between setting and receiving the stop signal via cascading.
–
0 ms = Another safety function has triggered the stop via the cascade.
 
–
The time is reset when acknowledged.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2124
CAS Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
4
SD-In4
0x2125:001
CAS: Stop delay
–
Read only: x ms
 
Delay between setting and receiving the stop signal via cascading.
–
0 ms = Another safety function has triggered the stop via the cascade.
 
–