Functional description
PDSS
–
PDSS uses the parameterized values for the maximum speed, for the decelerations and for the absolute end positions to calculate the maximum speed at each position in order to ensure timely standstill at the position limits.
–
In addition, two creep speeds (SCS) can be parameterized to approach the position limits more slowly.
–
From the end positions, the drive can travel with maximum acceleration.
If the motion control of the drive is within the monitoring limits:
–
Output of the status message: PDSS positive observed
–
In status word bit 16
–
Via a safe output (depending on the version)
–
Output of the status message: PDSS negative observed
–
In status word bit 17
–
Via a safe output (depending on the version)
Safe network interfaces