Setting

Please note when setting the parameters:
–
The internal brake module must control the holding brake.
 
–
"Normal" must be parameterized for the brake polarity.
 
–
Other settings are not compatible with the SBC function.
 
 
The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28E4
SBC Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28E5
SBC Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28E6:001
SBC: Brake mode
–
Safety parameter (+Safety parameter list+)
 
Selection whether the STO control is combined with the brake control.
1
SBC without STO
2
Automatic with STO
0x28E6:002
SBC: Delay SBC
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Time between SBC request and activation of the brake output.
0x28E6:003
SBC: Delay STO
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Time between SBC request and activation of STO in automatic mode.
0x28E6:004
SBC: Brake open delay
0 ... [0] ... 30000 ms
–
Safety parameter (+Safety parameter list+)
 
Time between SBC deactivation and brake opening.
0x28E7:001
SBC: "SBC active" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SBC active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28E7:002
SBC: "SBC activated" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SBC activated" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic