Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28D8:001
SCA: SCA1 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Definition of the lower position limit for the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
0x28D8:002
SCA: SCA2 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D8:003
SCA: SCA3 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D8:004
SCA: SCA4 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D9:001
SCA: SCA1 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Definition of the upper position limit for the function.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
0x28D9:002
SCA: SCA2 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D9:003
SCA: SCA3 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D9:004
SCA: SCA4 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28DA:001
SCA: "SCA1 within limits" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SCA1 within limits" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28DA:002
SCA: "SCA2 within limits" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SCA2 within limits" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28DA:003
SCA: "SCA3 within limits" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SCA3 within limits" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28DA:004
SCA: "SCA4 within limits" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SCA4 within limits" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic