Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28B0:001
SMS: Maximum speed Nmax
0 ... [0] ... 16000 rpm
–
Safety parameter (+Safety parameter list+)
 
Activation of the SMS function and selection of the maximum speed.
Nmax = 0 rpm deactivates the function.
0x28B0:002
SMS: Response (n>Nmax)
–
Safety parameter (+Safety parameter list+)
 
Response when Nmax is exceeded.
0
STO
1
SS1
2
SS2
0x28B1
SMS "SMS observed" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the ""SMS monitored" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic