Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x289D
SOS Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x289E
SOS Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x289F:001
SOS: Tolerance window (Delta p=0)
0 ... [8192] ... 327680 incr.
–
Safety parameter (+Safety parameter list+)
 
If the position change is within the tolerance window, the status "
D
p = 0" is valid.
0x289F:002
SOS: Restart
–
Safety parameter (+Safety parameter list+)
 
Restart behavior after the function has been canceled.
0
Acknowledged restart
1
Automatic restart
0x289F:003
SOS: Maximum change of position
–
Read only: x incr.
 
Value of the maximum position change while SOS has been active.
The incremental position value is related to the motor encoder.
0x28A0
SOS "SOS observed" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SOS observed" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic