Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28C8
SLI Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28C9
SLI Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28CA:001
SLI: Increment size standard operation
0 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Number of increments for a safely limited increment in normal operation.
0x28CA:002
SLI: Error response standard operation
–
Safety parameter (+Safety parameter list+)
 
Response when the safe increment is exceeded in normal operation.
0
STO
1
SS1
2
SS2
0x28CA:003
SLI: Increment size special operation
0 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Number of increments for safely limited increment in special operation.
Number = 0 deactivates the function.
0x28CA:004
SLI: Maximum change of position
–
Read only: x incr.
 
Value of the position change while SLI has been active.
The incremental position value is related to the motor encoder.
0x28CB
SLI "SLI active" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SLI active" feedback.
0
Disabled
1
SD-Out1 positive logic
2