Setting

The mode of action of the parameters can be found in the dialog box for the function in the "Safety parameter list" in the engineering tool used.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x28D0:001
SLP: SLP1 - Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28D0:002
SLP: SLP2 - Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28D0:003
SLP: SLP3 - Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28D0:004
SLP: SLP4 - Source SD-In
–
Safety parameter (+Safety parameter list+)
 
Selection of a safe input as a trigger source for the function.
0
Disabled
1
SD-In1
2
SD-In2
3
SD-In3
4
SD-In4
0x28D1:001
SLP: SLP1 - Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28D1:002
SLP: SLP2 - Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28D1:003
SLP: SLP3 - Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28D1:004
SLP: SLP4 - Source S-Bus
–
Safety parameter (+Safety parameter list+)
 
Selection of the safety bus as the trigger source for the function.
0
Disabled
1
Activated
0x28D2:001
SLP: SLP1 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Definition of the lower position limit for monitoring.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
0x28D2:002
SLP: SLP2 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D2:003
SLP: SLP3 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D2:004
SLP: SLP4 - Lower position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D3:001
SLP: SLP1 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
Definition of the upper position limit for monitoring.
1-encoder system The incremental position value is related to the motor encoder.
2-encoder system The incremental position value is related to the load encoder.
0x28D3:002
SLP: SLP2 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D3:003
SLP: SLP3 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D3:004
SLP: SLP4 - Upper position limit
-2147483648 ... [0] ... 2147483647 incr.
–
Safety parameter (+Safety parameter list+)
 
0x28D4:001
SLP: SLP1 - Error response
–
Safety parameter (+Safety parameter list+)
 
Response when a position limit is exceeded.
0
STO
1
SS1
2
SS2
0x28D4:002
SLP: SLP2 - Error response
–
Safety parameter (+Safety parameter list+)
 
Response when a position limit is exceeded.
0
STO
1
SS1
2
SS2
0x28D4:003
SLP: SLP3 - Error response
–
Safety parameter (+Safety parameter list+)
 
Response when a position limit is exceeded.
0
STO
1
SS1
2
SS2
0x28D4:004
SLP: SLP4 - Error response
–
Safety parameter (+Safety parameter list+)
 
Response when a position limit is exceeded.
0
STO
1
SS1
2
SS2
0x28D5:001
SLP: "SLP1 observed" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SLP1 active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28D5:002
SLP: "SLP2 observed" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SLP2 active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28D5:003
SLP: "SLP3 observed" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SLP3 active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic
0x28D5:004
SLP: "SLP4 observed" - Output
–
Safety parameter (+Safety parameter list+)
 
Selection of the safe output for the "SLP4 active" feedback.
0
Disabled
1
SD-Out1 positive logic
2
SD-Out1 negative logic