0x2022:001
|
Device commands: Load default settings
–
Setting can only be changed if the inverter is disabled.
|
1 = reset all parameters in the RAM memory of the inverter to the default setting that is stored in the inverter firmware.
–
All parameter changes made by the user are lost during this process!
–
It may take some seconds to execute the task. When the task has been executed successfully, the value 0 is shown.
–
Loading parameters has a direct effect on the cyclic communication: The data exchange for control is interrupted and a communication error is generated.
|
|
0
|
Off / ready
|
Only status feedback
|
|
1
|
On / start
|
Execute device command
|
|
2
|
In progress
|
Only status feedback
|
|
3
|
Action cancelled
|
|
4
|
No access
|
|
5
|
No access (Device disabled)
|
|
0x2022:039
|
Device commands: Load TA default settings
–
Setting can only be changed if the inverter is disabled.
|
|
|
0
|
Off / ready
|
Only status feedback
|
|
1
|
On / start
|
Execute device command
|
|
2
|
In progress
|
Only status feedback
|
|
3
|
Action cancelled
|
|
4
|
No access
|
|
5
|
No access (Device disabled)
|