Saving/loading the parameter settings
If parameter settings of the inverter are changed, these changes at first are only made in the RAM memory of the inverter. In order to save the parameter settings with mains failure protection, the inverter is provided with the corresponding device command in the parameter.0x2022:003
The following data is stored on the SD card and is protected against power failure.
–
Parameter set, including the associated checksum (CRC) of the parameter set
–
Safety parameters, including the associated checksum (CRC) of the safety parameters
–
Firmware, including the associated checksum (CRC) of the firmware
–
PLC boot application, including the associated checksum (CRC) of the boot application
–
PLC data to be saved persistently (PERSISTENT and RETAIN variables), for example:
–
Motion axis data required to reconstruct the position
–
CAM curve data
–
Own SFTP key (Customer.ppk)
–
EtherCAT second station address
–
PROFINET station name
–
IP addresses for Ethernet and PROFINET
Parameter
CAUTION!