Saving/loading the parameter settings

If parameter settings of the inverter are changed, these changes at first are only made in the RAM memory of the inverter. In order to save the parameter settings with mains failure protection, the inverter is provided with the corresponding device command in the parameter.0x2022:003
 
The following data is stored on the SD card and is protected against power failure.
–
Parameter set, including the associated checksum (CRC) of the parameter set
 
–
Safety parameters, including the associated checksum (CRC) of the safety parameters
 
–
Firmware, including the associated checksum (CRC) of the firmware
 
–
PLC boot application, including the associated checksum (CRC) of the boot application
 
–
PLC data to be saved persistently (PERSISTENT and RETAIN variables), for example:
 
–
Motion axis data required to reconstruct the position
 
–
CAM curve data
 
 
–
Own SFTP key (Customer.ppk)
 
–
EtherCAT second station address
 
–
PROFINET station name
 
–
IP addresses for Ethernet and PROFINET
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2022:003
Device commands: Save user data
1 = save current parameter settings in the user memory of the memory module with mains failure protection.
–
This process may take some seconds. When the device command has been executed successfully, the value 0 is shown.
 
–
Do not switch off the supply voltage during the saving process and do not unplug the memory module from the device!
 
–
When the device is switched on, all parameters are automatically loaded from the user memory of the memory module to the RAM memory of the device.
 
0
Off / ready
Only status feedback
1
On / start
Execute device command
2
In progress
Only status feedback
3
Action cancelled
4
No access
5
No access (Device disabled)
101
No SD card connected
102
SD card is write protected
103
SD card is full
0x2022:040
Device commands: Parameter-Backup
–
Setting can only be changed if the inverter is disabled.
 
–
When the device command has been executed successfully, the value 0 is shown.
 
–
While the device command is being executed, do not switch off the supply voltage and do not remove the memory module!
 
CAUTION!
–
In parallel, the file "\firmware\update_data.tar" is stored on the SD card.
 
–
When booting, the firmware level of the device is compared with the firmware level of the file.
 
–
If the firmware versions are different, the device is automatically updated to the firmware version of the file!
 
0
Off / ready
Only status feedback
1
On / start
Execute device command
2
In progress
Only status feedback
3
Action cancelled
4
No access
5
No access (Device disabled)
20
20%
40
40%
60
60%
80
80%
100
100%
101
No SD card connected
102
SD card is write protected
103
SD card is full
0x2022:043
Device commands: Restore
–
Setting can only be changed if the inverter is disabled.
 
–
When the device command has been executed successfully, the value 0 is shown.
 
–
While the device command is being executed, do not switch off the supply voltage and do not remove the memory module!
 
0
Off / ready
Only status feedback
1
On / start
Execute device command
2
In progress
Only status feedback
3
Action cancelled
4
No access
5
No access (Device disabled)
20
20%
40
40%
60
60%
80
80%
100
100%
101
No SD card connected