Acknowledgement with confirmation button S82
If the device detects a modified parameter set or a changed safety address during initialization, for example, the device requests an acknowledgement with confirmation button S82.
|
LED "RDY" (yellow)
|
LED "ERR" (red)
|
Status
|
Meaning
|
|
on
|
blinking red 1 Hz
|
Restart acknowledgement requested
|
During startup, a modified parameter set was detected in the "Init" state.
|
|
blinking red 2 Hz
|
During startup, a changed safety address was detected in the "Init" state.
|
||
|
blinking red
|
During startup, a changed assignment between OCT encoder and inverter was detected in the "Init" state.
|
All requests are acknowledged with the same steps.
The acknowledgement procedure is aborted if the reaction time of 2.5 seconds is exceeded. The acknowledgement procedure must be repeated.
Fig. 1: Sequence of the acknowledgement procedure
RDY
LED "RDY"
S82
Confirmation button S82
t
Time axis
tmax
Maximum permissible response time
To acknowledge the request with the S82 confirmation button:
Precondition:
✓
The "RDY" LED is lit.
✓
The "ERR" LED is blinking.
1.
Press and hold the S82 button.
The "RDY" LED starts blinking.
2.
The "RDY" LED goes off after 3 seconds.
3.
Release the S82 button after a maximum of 2.5 seconds.
The "RDY" LED is lit.
4.
Press and hold the S82 button after a maximum of 2.5 seconds.
The "RDY" LED starts blinking.
5.
The "RDY" LED goes off after 3 seconds.
6.
Release the S82 button after a maximum of 2.5 seconds.
The acknowledgement is successfully completed.
The action is recorded in the inverter logbook.
The action is recorded in the inverter logbook.
7.
Use a function test to ensure that the acknowledgement has led to the correct result.
If the parameter set is invalid, an error is reported and the "ERR" LED starts blinking.