Acknowledgement with confirmation button S82

If the device detects a modified parameter set or a changed safety address during initialization, for example, the device requests an acknowledgement with confirmation button S82.
 
Display for requested acknowledgement
LED "RDY" (yellow)
LED "ERR" (red)
Status
Meaning
on
blinking red 1 Hz
Restart acknowledgement requested
During startup, a modified parameter set was detected in the "Init" state.
blinking red 2 Hz
During startup, a changed safety address was detected in the "Init" state.
blinking red
During startup, a changed assignment between OCT encoder and inverter was detected in the "Init" state.
 
All requests are acknowledged with the same steps.
The acknowledgement procedure is aborted if the reaction time of 2.5 seconds is exceeded. The acknowledgement procedure must be repeated.
 
 
Fig. 1: Sequence of the acknowledgement procedure
RDY
LED "RDY" 
 
S82
Confirmation button S82 
 
t
Time axis 
 
tmax
Maximum permissible response time 
 
 
 
To acknowledge the request with the S82 confirmation button:
Precondition:
✓
The "RDY" LED is lit.
 
✓
The "ERR" LED is blinking.
 
1.
Press and hold the S82 button.
The "RDY" LED starts blinking.
 
2.
The "RDY" LED goes off after 3 seconds.
 
3.
Release the S82 button after a maximum of 2.5 seconds.
The "RDY" LED is lit.
 
4.
Press and hold the S82 button after a maximum of 2.5 seconds.
The "RDY" LED starts blinking.
 
5.
The "RDY" LED goes off after 3 seconds.
 
6.
Release the S82 button after a maximum of 2.5 seconds.
The acknowledgement is successfully completed.
The action is recorded in the inverter logbook.
 
7.
Use a function test to ensure that the acknowledgement has led to the correct result.
 
If the parameter set is invalid, an error is reported and the "ERR" LED starts blinking.