0x2114:001
|
Parameter set: Version
–
Safety parameter (+Safety parameter list+)
|
Display of the version of the safe parameter set.
Changes can be made via the +Safety parameter list+ dialog.
|
|
1003
|
i950 ES V1.0
|
Versions of the safe parameter set for i950 extended safety.
|
|
10103
|
i950 ES V1.1
|
|
10203
|
i950 ES V1.2
|
|
10303
|
i950 ES V1.3
|
|
0x2114:002
|
Parameter set: Project CRC
0 ... [0] ... 4294967295
|
Project CRC of the safe parameter set.
|
|
0x2115:001
|
Parameter set: Status
|
Current status of the safe parameter set.
|
|
0
|
No parameter set
|
|
|
1
|
Valid parameter set
|
|
4
|
CRC error
|
|
5
|
Version error
|
|
7
|
Plausibility error
|
|
8
|
Assignment error
|
|
9
|
Local read error
|
|
10
|
Communication error with basic device
|
|
11
|
Faulty release
|
|
12
|
Different CRCs
|
|
13
|
Changed parameter set
|
|
14
|
Parameter set checked
|
|
15
|
Parameter set check active
|
|
0x2115:002
|
Parameter set: Current CRC
|
Display of the current parameter CRC from the safe parameter set.
|
|
0x2115:003
|
Parameter set: Last valid CRC
|
Display of the last valid parameter set CRC.
|
|
0x2115:004
|
Parameter set: Parameter setting time stamp
|
Time when the parameter set is taken over from the device as the value of the power-on time meter.
|
|
0x2115:005
|
Parameter set: Error information 1
|
Error number in case of a plausibility error (0x2115:001 = 7).
|
|
0x2115:006
|
Parameter set: Error information 2
|
Reserved
|
|
0x2115:007
|
Parameter set: Error information 3
|
|
0x2115:008
|
Parameter set: Current CRC without specific identifiers
|
Display of the current parameter CRC from the safe parameter set without safety address.
|