Synchronisation with "distributed clocks" (DC)

The Distributed Clocks (DC) functionality enables an exact time leveling for applications, in which several axes execute simultaneous, coordinated movements. The data is accepted synchronously with the PLC program. For DC synchronization, all slaves are synchronized with a reference clock, the so-called "DC master".
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2580:001
Distributed Clocks: Real time status
–
Read only
 
Since its switch-on, the inverter has not yet received any real time information from outside.
The inverter still works with a time based on the time of the last switch-off or the time stamp of the firmware.
0
Not adjusted
Since its switch-on, the inverter has not yet received any real time information from outside.
1
Adjusted once
2
Adjusted cyclically
0x2580:002
Distributed Clocks: First setting time
–
Read only: x ns
 
Display of the time when the inverter has received a real time information from outside for the for first time after its switch-on.
In the "No real time information received yet", the value "0" is displayed.
0x2580:003
Distributed Clocks: Newest setting time
–
Read only: x ns
 
Display of the time when the inverter has most recently received a real time information from outside.
0x2580:004
Distributed Clocks: Current time
–
Read only: x ns
 
Display of the time information currently used by the inverter (device time).