0x6041
|
CiA status word
|
Mappable CiA status word with bit assignment according to device profile CiA 402.
|
|
Bit
0
|
Ready to switch on
|
1 = drive ready to start
|
|
Bit
1
|
Switched on
|
1 = drive switched-on
|
|
Bit
2
|
Operation enabled
|
1 = operation enabled
|
|
Bit
3
|
Fault
|
1 = fault or trouble active
|
|
Bit
4
|
Voltage enabled
|
1 = DC bus ready for operation
|
|
Bit
5
|
Quick stop disabled
|
0 = quick stop active
|
|
Bit
6
|
Switch on disabled
|
1 = operation inhibited
|
|
Bit
7
|
Warning
|
1 = warning active
|
|
Bit
8
|
RPDOs disabled
|
1 = cyclic PDOs have been deactivated
|
|
Bit
9
|
CiA control enabled
|
1 = inverter can receive commands via network.
–
Bit is not set in the operating mode 0x6060 = "MS: Velocity mode [-2]".
|
|
Bit
10
|
Setpoint reached
|
1 = the actual speed is in the window.
|
|
Bit
11
|
Internal limit active
|
1 = internal limitation of a setpoint active
|
|
Bit
12
|
Operation mode specific
|
1 = operation enabled and no test mode activated. (no internal setpoint generation active.)
|
|
Bit
13
|
Operation mode specific
|
1 ≡ following error active
|
|
Bit
14
|
Brake released or switching
|
|
|
Bit
15
|
STO not active
|
0 = STO is active or impermissible state at the safe inputs SIA and SIB (inverter disabled)
1 = STO is not active (inverter enabled)
|