Software limit switches
The parameterisable software end switches limit the traversing range set via the software.
The software end switches are not active for the "Modulo" traversing range and when a reference run is active.
In the following situations, the software end switches are evaluated, monitored, and shown in the status word when triggered:
0x500A:005 Bit 6
0x500A:005 Bit 6–
The home position is known to the drive.
0x500A:005 Bit 5
0x500A:005 Bit 5–
The software limit switches are effectively switched.
0x500A:050
0x500A:050–
The monitoring was not deactivated from within the application.
0x500A:005 Bit 24
0x500A:005 Bit 24In the device states "Deactivated" or "Error stop", traversing the software limit switch does not result in an error.
If the software limit switches are exceeded, the set error response is triggered.
0x500A:105
0x500A:105The software limit switches can be retracted in the direction of the permitted traversing range.