Status signals
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x5030:110
|
Status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
||
|
Bit
0
|
Ready for operation
|
Axis ready for switch-on.
|
|
|
Bit
1
|
Homing active
|
Homing is active.
|
|
|
Bit
2
|
Operation enabled
|
Axis is enabled.
|
|
|
Bit
3
|
Fault
|
An error is active.
|
|
|
Bit
4
|
Homing done
|
Homing was completed successfully.
|
|
|
Bit
5
|
Application quick stop active
|
Quick stop has been triggered.
|
|
|
Bit
6
|
Manual jog active
|
Manual operation is active.
|
|
|
Bit
7
|
Warning
|
A warning is active.
|
|
|
Bit
8
|
Halt active
|
A stop was triggered in the application.
|
|
|
Bit
9
|
Motor control in limitation
|
The motor control is in limitation.
|
|
|
Bit
10
|
Set position reached
|
Actual position = setpoint position
|
|
|
Bit
11
|
Abort busy
|
The active movement is canceled.
|
|
|
Bit
12
|
Standstill
|
Standstill reached.
|
|
|
Bit
13
|
Direction of rotation inverted
|
Direction of rotation is inverted.
|
|
|
Bit
14
|
Brake opened
|
The holding brake is open.
|
|
|
Bit
15
|
STO active
|
Safe Torque Off is active.
|
|
|
Bit
16
|
Active profile bit 0
|
Active profile (bit-coded).
Bit 0 represents the decimal 1.
Bit 1 represents the decimal 2.
Bit 2 represents the decimal 4.
Bit 3 represents the decimal 8.
|
|
|
Bit
17
|
Active profile bit 1
|
||
|
Bit
18
|
Active profile bit 2
|
||
|
Bit
19
|
Active profile bit 3
|
||
|
Bit
20
|
Positioning profile busy
|
Positioning is active.
|
|
|
Bit
21
|
Positioning profile done
|
Positioning is completed.
|
|
|
Bit
22
|
Negative hardware limit switch active
|
The negative hardware limit switch has been triggered.
|
|
|
Bit
23
|
Positive hardware limit switch active
|
The positive hardware limit switch has been triggered.
|
|
|
Bit
24
|
Touch probe detected
|
Touch probe has been detected.
|
|
|
Bit
25
|
Status bit 25 (reserved)
|
Bit without function
|
|
|
Bit
26
|
Status bit 26 (reserved)
|
||
|
Bit
27
|
Torque setpoint limited
|
The setpoint torque is in limitation.
|
|
|
Bit
28
|
External position active
|
External position is activated.
|
|
|
Bit
29
|
External velocity active
|
External speed is activated.
|
|
|
Bit
30
|
External acceleration/deceleration/jerk active
|
External acceleration values, external deceleration values, and the external jerk are active.
|
|
|
Bit
31
|
External torque limit active
|
The external torque limits are active.
|
|
|
0x5030:111
|
Status signals limiter
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
Extended Safety - status of the monitoring functions
|
|
|
Bit
0
|
STO active
|
Safe torque off (STO) active.
The axis is safely switched to torqueless operation.
|
|
|
Bit
1
|
SS1 active
|
Safe stop 1 (SS1) active.
Subsequently, the drive is torqueless (STO).
|
|
|
Bit
2
|
SS2 active
|
Safe stop 2 (SS2) active.
The drive then changes to the safe operational stop (SOS).
|
|
|
Bit
3
|
SOS active
|
Safe operational stop (SOS) active.
The reached position is actively held.
|
|
|
Bit
4
|
SLS1 active
|
Safely limited speed (SLS1) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
5
|
SLS2 active
|
Safely limited speed (SLS2) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
6
|
SLS3 active
|
Safely limited speed (SLS3) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
7
|
SLS4 active
|
Safely limited speed (SLS4) active.
The travel profile changes according to the parameters set for it.
|
|
|
Bit
8
|
SDpos active
|
Safe direction (SDI) active.
Only the positive direction is allowed.
|
|
|
Bit
9
|
SDneg active
|
Safe direction (SDI) active.
Only the negative direction is allowed.
|
|
|
Bit
10
|
SLI active
|
Safely limited increment (SLI) active.
A maximum permissible change in position is monitored.
|
|
|
Bit
11
|
SSE active
|
Safe stop emergency (SSE) active.
|
|
|
Bit
12
|
ES active
|
Enable switch (ES) active.
The stop functions in special mode are overridden.
|
|
|
Bit
13
|
OMS active
|
Operation mode selector (OMS) active.
Special operation is active.
|
|
|
0x5030:112
|
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
|
Display of the actual velocity
|
|
|
0x5030:114
|
Error code
0 ... [0] ... 4294967295
|
Display of the current error number.
|
|
|
0x5030:115
|
Actual torque
-214748.3648 ... [0.0000] ... 214748.3647 Nm
|
Display of the actual torque
|
|
|
0x5030:116
|
Display value 1
0 ... [0] ... 4294967295
|
Display of the monitor signal "Display value 1"
Selection:
0x5030:006 |
|
|
0x5030:117
|
Display value 2
0 ... [0] ... 4294967295
|
Display of the monitor signal "Display value 2"
Selection:
0x5030:007 |
|
|
0x5030:123
|
Actual position
-214748.3648 ... [0.0000] ... 214748.3647
|
Display of the actual position
|
|
|
0x5030:150
|
Read external profile data in edge-controlled manner
|
Acceptance of the profile data preselected externally.
|
|
|
0
|
FALSE
|
The external profile data are directly accepted.
|
|
|
1
|
TRUE
|
The external profile data are only accepted with control bit 20 = TRUE.
|
|
0x5030:006