Example: System bus slave is master value master
If the system bus master is not the master value master, the parameter Parameter source for wörds 0 … 3 must be set to the corresponding source. 0x5021:010
Fig. 1: Example 2 - System bus slave is master value master
M
System bus master
VM
Virtual master
S
Slave
If the virtual master for master value generation is not used in the system bus master (
Example: System bus master is master value master) but in slave 2 (S2), the parameter Parameter source for words 0 … 3 must be set to Slave 2 [3] . 0x5021:010
Example: System bus master is master value master) but in slave 2 (S2), the parameter Parameter source for words 0 … 3 must be set to Slave 2 [3] . 0x5021:010|
System bus
Input words
|
Master
|
Slave 1
|
Slave 2
|
. . .
|
Slave 15
|
|
|
00
|
Cycle length of the master axis
(0x5021:150)
|
0x5021: 010
03: Slave 2
|
. . .
|
0x5021:010
03: Slave 2
|
||
|
01
|
Master position value
(0x5021:151)
|
|||||
|
02
|
Master speed value
(0x5021:152)
|
|||||
|
03
|
Master acceleration value
(0x5021:153)
|
|||||
|
04
|
Torque of the master axis
(0x5021:154)
|
0x5021:020
01: Master
|
0x5021:021
01: Master
|
0x5021:022
01: Master
|
0x5021:035
01: Master
|
|
|
05
|
Time stamp of the master axis
(0x5021:155)
|
0x5021:040
01: Master
|
0x5021:041
01: Master
|
0x5021:042
01: Master
|
0x5021:055
01: Master
|
|
|
06
|
Free input word
(0x5021:156)
|
0x5021:060
01: Master
|
0x5021:061
01: Master
|
0x5021:062
01: Master
|
0x5021:075
01: Master
|
|
|
07
|
Free input word
(0x5021:157)
|
0x5021:080
01: Master
|
0x5021:081
01: Master
|
0x5021:082
01: Master
|
0x5021:095
01: Master
|
|