Example: Using time stamp of another axis

The touch probe time stamp of the technology application Sync and correction (S1) is to be used by the technology application Table Positioning (S2). The master value master is the virtual master in the system bus master.
Fig. 1: Example 3 - Using the timestamp of another axis
M
System bus master 
 
VM
Virtual master 
 
S
Slave 
 
TP
Touch probe 
 
 
In order to allow the time stamp of Slave 1 to be used by Slave 2 as well, the parameter Parameter source for word 5 (Slave 2) must be set to Slave 1 [2] (see following table). 0x5021:042
System bus
Input words
Master
Slave 1
Slave 2
. . .
Slave 15
00
Cycle length of the master axis
(0x5021:150)
0x5021: 010
01: Master
. . .
0x5021:010
01: Master
01
Master position value
(0x5021:151)
02
Master speed value
(0x5021:152)
03
Master acceleration value
(0x5021:153)
04
Torque of the master axis
(0x5021:154)
0x5021:020
01: Master
0x5021:021
01: Master
0x5021:022
01: Master
0x5021:035
01: Master
05
Time stamp of the master axis
(0x5021:155)
0x5021:040
01: Master
0x5021:041
01: Master
0x5021:042
02: Slave 1
0x5021:055
01: Master
06
Free input word
(0x5021:156)
0x5021:060
01: Master
0x5021:061
01: Master
0x5021:062
01: Master
0x5021:075
01: Master
07
Free input word
(0x5021:157)
0x5021:080
01: Master
0x5021:081
01: Master
0x5021:082
01: Master
0x5021:095
01: Master
As shown in the table, the parameters 0x5021:020 ... 095 can also be used for the distribution of the torque values and for specific data from the technology application.