Example: Using time stamp of another axis
The touch probe time stamp of the technology application Sync and correction (S1) is to be used by the technology application Table Positioning (S2). The master value master is the virtual master in the system bus master.
Fig. 1: Example 3 - Using the timestamp of another axis
M
System bus master
VM
Virtual master
S
Slave
TP
Touch probe
In order to allow the time stamp of Slave 1 to be used by Slave 2 as well, the parameter Parameter source for word 5 (Slave 2) must be set to Slave 1 [2] (see following table). 0x5021:042
|
System bus
Input words
|
Master
|
Slave 1
|
Slave 2
|
. . .
|
Slave 15
|
|
|
00
|
Cycle length of the master axis
(0x5021:150)
|
0x5021: 010
01: Master
|
. . .
|
0x5021:010
01: Master
|
||
|
01
|
Master position value
(0x5021:151)
|
|||||
|
02
|
Master speed value
(0x5021:152)
|
|||||
|
03
|
Master acceleration value
(0x5021:153)
|
|||||
|
04
|
Torque of the master axis
(0x5021:154)
|
0x5021:020
01: Master
|
0x5021:021
01: Master
|
0x5021:022
01: Master
|
0x5021:035
01: Master
|
|
|
05
|
Time stamp of the master axis
(0x5021:155)
|
0x5021:040
01: Master
|
0x5021:041
01: Master
|
0x5021:042
02: Slave 1
|
0x5021:055
01: Master
|
|
|
06
|
Free input word
(0x5021:156)
|
0x5021:060
01: Master
|
0x5021:061
01: Master
|
0x5021:062
01: Master
|
0x5021:075
01: Master
|
|
|
07
|
Free input word
(0x5021:157)
|
0x5021:080
01: Master
|
0x5021:081
01: Master
|
0x5021:082
01: Master
|
0x5021:095
01: Master
|
|
As shown in the table, the parameters 0x5021:020 ... 095 can also be used for the distribution of the torque values and for specific data from the technology application.