0x2010:001
|
Device event monitor: EreignisortEvent location
|
Display of the event location for the currently pending event.
|
|
0
|
No error
|
|
|
1
|
Functional safety
|
|
4
|
Basic settings
|
|
5
|
Communication
|
|
6
|
Kinematics
|
|
7
|
Motion
|
|
8
|
Technology application
|
|
0x2010:002
|
Device event monitor: Severity
|
Display of the severity level for the currently active event.
|
|
0
|
No response
|
|
|
1
|
Fault > CiA402
|
|
2
|
Warning
|
|
11
|
Information
|
|
|
13
|
Warning locked
|
|
15
|
Trouble > only logbook entry
|
|
16
|
Trouble
|
|
18
|
Fault > only logbook entry
|
|
19
|
Fault > application quick stop > quick stop
|
|
20
|
Fault > inverter quick stop > quick stop
|
|
21
|
Fault > inverter quick stop > inverter disabled
|
|
23
|
Fault > inverter disabled
|
|
0x2010:003
|
Device event monitor: Event status
|
Display of the event status for the currently pending event.
|
|
0
|
No event active
|
|
1
|
Reset possible
|
|
2
|
Reset not possible
|
|
0x2010:005
|
Device event monitor: Number of current event
|
Display of the event ID for the currently pending event.
|
|
Bit
0
|
|
|
|
0x2010:006
|
Device event monitor: Time stamp of current event
|
Display of the time stamp for the current upcoming event.
|
|
0x2012:001
|
Device information: SD card status
|
|
|
0
|
No SD card connected
|
|
1
|
SD card connected
|
|
0x2012:002
|
Device information: Application Credit available
|
|
0x2013:001
|
Application information: Active application
|
|
0
|
CiA 402
|
|
1
|
"CiA 402 advanced" technology application
|
|
5
|
"AC Drive Profile" technology application
|
|
10
|
"Speed Control" technology application
|
|
20
|
"Table Positioning" technology application
|
|
40
|
"Electronic Gearbox" technology application
|
|
41
|
"Sync and Correction" technology application
|
|
50
|
"Winder Dancer" technology application
|
|
51
|
"Winder Tension" technology application
|
|
100
|
"User" technology application
|
|
0x2013:002
|
Application information: Application Credit required
|
|
0x2040
|
Access protection status
|
Bit-coded display of the active access protection after login by PIN1/PIN2.
|
|
Bit
0
|
No write access
|
|
Bit
1
|
Only favorites changeable
|
|
0x2539:001
|
Hardware-Diagnose: External supply voltage
|
|
|
0x2539:002
|
Hardware-Diagnose: Control board temperature
|
|
0x2823
|
Status of axis commands
|
|
0x282A:001
|
Status words: Cause of disable
|
Bit-coded display of the cause(s) for disabled inverter.
|
|
Bit
2
|
Axis command
|
1 = the inverter was disabled via axis command 0x2822:001.
|
|
Bit
7
|
Drive not ready
|
1 = the inverter was disabled internally since the drive was not ready for operation.
Possible causes:
–
Under/overvoltage in the DC bus
–
Defective device hardware
|
|
Bit
12
|
CiA402 Inverter disabled
|
1 = the inverter was disabled by the internal state machine.
The bit is only set if
–
Operating mode 0x6060 = "CiA: Velocity mode (vl) [2]" and
–
state machine in the "Switch on disabled" state and
–
the state change has not been carried out via the "Disable operation" command.
|
|
Bit
14
|
Safety
|
1 = the inverter has been disabled by the integrated safety system.
|
|
Bit
16
|
PROFINET energy pause active
|
-
|
|
0x282A:004
|
Status words: Extended status word
|
Bit-coded status word.
|
|
Bit
0
|
Brake is opened
|
-
|
|
Bit
1
|
Reserved
|
|
0x2831
|
Inverter status word
|
Bit coded status word of the internal motor control.
|
|
Bit
0
|
Position controller in limitation
|
-
|
|
Bit
1
|
Speed setpoint 1 limited
|
1 = input of speed controller 1 in limitation.
|
|
Bit
2
|
Speed controller in limitation
|
1 = output of speed controller 1 in limitation.
|
|
Bit
3
|
Torque setpoint limited
|
1 = setpoint torque in limitation.
|
|
Bit
4
|
Q-current setpoint limited
|
1 = setpoint current in limitation.
|
|
Bit
5
|
Speed setpoint 2 limited
|
1 = input of speed controller 2 in "torque mode" in limitation.
|
|
Bit
6
|
Upper speed limit active
|
1 = in "torque mode", the speed is limited to upper speed limit 0x2946:001 .
|
|
Bit
7
|
Lower speed limit active
|
1 = in "torque mode", the speed is limited to lower speed limit 0x2946:002 .
|
|
Bit
8
|
Flying restart active
|
-
|
|
Bit
9
|
Flying restart completed
|
|
Bit
10
|
Output frequency limited
|
1 = setpoint frequency with V/f operation in limitation.
|
|
Bit
11
|
Magnetization completed
|
1 = Magnetisation completed during V/f operation.
Otherwise 0.
|
|
Bit
12
|
Motor phase error
|
1 = motor phase failure detection active.
|
|
Bit
13
|
Feedback open circuit
|
-
|
|
Bit
14
|
Error reset blocking time active
|
1 = the error can only be reset when the blocking time has elapsed.
|
|
Bit
15
|
Clamp active
|
-
|
|
0x2833
|
Inverter status word 2
|
Bit-coded status word 2 of the inverter.
|
|
Bit
0
|
Motor encoder modified
|
|
|
Bit
1
|
Manual test mode active
|
1 = manual test mode active.
|
|
Bit
2
|
Manual control active
|
1 = manual control active.
|
|
Bit
4
|
Motor encoder = absolute value encoder
|
-
|
|
Bit
5
|
Motor encoder absolute position available
|
|
Bit
6
|
DC braking active
|
1 = DC braking active.
|
|
Bit
7
|
Motor encoder angle drift invalid
|
-
|
|
Bit
8
|
Load encoder modified
|
|
Bit
9
|
Load encoder angle drift invalid
|
|
Bit
10
|
Load encoder = absolute value encoder
|
|
Bit
11
|
Load encoder absolute position available
|
|
Bit
12
|
Brake open
|
|
|
Bit
13
|
Cable check active
|
|
Bit
14
|
Mains failure detected
|
|
0x284F
|
Current error
|
Test display of the current error.
–
This object contains a reference for the text to be displayed from the ESI file as well as the substitution values for all wildcards in this text.
–
The text has the same structure as the diagnostic messages in the history buffer.
|
|
0x603F
|
Error code
|
Error message
|
|
Bit
0
|
|
|